cimpy.cgmes_v2_4_15.WindProtectionIEC module
- class cimpy.cgmes_v2_4_15.WindProtectionIEC.WindProtectionIEC(WindTurbineType1or2IEC=None, WindTurbineType3or4IEC=None, fover=0.0, funder=0.0, tfover=0.0, tfunder=0.0, tuover=0.0, tuunder=0.0, uover=0.0, uunder=0.0, *args, **kw_args)[source]
The grid protection model includes protection against over and under voltage, and against over and under frequency. Reference: IEC Standard 614000-27-1 Section 6.6.6.
- WindTurbineType1or2IEC:
Wind generator type 1 or 2 model with which this wind turbine protection model is associated. Default: None
- WindTurbineType3or4IEC:
Wind generator type 3 or 4 model with which this wind turbine protection model is associated. Default: None
- fover:
Set of wind turbine over frequency protection levels (). It is project dependent parameter. Default: 0.0
- funder:
Set of wind turbine under frequency protection levels (). It is project dependent parameter. Default: 0.0
- tfover:
Set of corresponding wind turbine over frequency protection disconnection times (). It is project dependent parameter. Default: 0.0
- tfunder:
Set of corresponding wind turbine under frequency protection disconnection times (). It is project dependent parameter. Default: 0.0
- tuover:
Set of corresponding wind turbine over voltage protection disconnection times (). It is project dependent parameter. Default: 0.0
- tuunder:
Set of corresponding wind turbine under voltage protection disconnection times (). It is project dependent parameter. Default: 0.0
- uover:
Set of wind turbine over voltage protection levels (). It is project dependent parameter. Default: 0.0
- uunder:
Set of wind turbine under voltage protection levels (). It is project dependent parameter. Default: 0.0
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’