cimpy.cgmes_v2_4_15.GovHydroWPID module
- class cimpy.cgmes_v2_4_15.GovHydroWPID.GovHydroWPID(d=0.0, gatmax=0.0, gatmin=0.0, gv1=0.0, gv2=0.0, gv3=0.0, kd=0.0, ki=0.0, kp=0.0, mwbase=0.0, pgv1=0.0, pgv2=0.0, pgv3=0.0, pmax=0.0, pmin=0.0, reg=0.0, ta=0.0, tb=0.0, treg=0.0, tw=0.0, velmax=0.0, velmin=0.0, *args, **kw_args)[source]
Woodward PID Hydro Governor.
- d:
Turbine damping factor (D). Unit = delta P / delta speed. Default: 0.0
- gatmax:
Gate opening Limit Maximum (Gatmax). Default: 0.0
- gatmin:
Gate opening Limit Minimum (Gatmin). Default: 0.0
- gv1:
Gate position 1 (Gv1). Default: 0.0
- gv2:
Gate position 2 (Gv2). Default: 0.0
- gv3:
Gate position 3 (Gv3). Default: 0.0
- kd:
Derivative gain (Kd). Typical Value = 1.11. Default: 0.0
- ki:
Reset gain (Ki). Typical Value = 0.36. Default: 0.0
- kp:
Proportional gain (Kp). Typical Value = 0.1. Default: 0.0
- mwbase:
Base for power values (MWbase) (>0). Unit = MW. Default: 0.0
- pgv1:
Output at Gv1 PU of MWbase (Pgv1). Default: 0.0
- pgv2:
Output at Gv2 PU of MWbase (Pgv2). Default: 0.0
- pgv3:
Output at Gv3 PU of MWbase (Pgv3). Default: 0.0
- pmax:
Maximum Power Output (Pmax). Default: 0.0
- pmin:
Minimum Power Output (Pmin). Default: 0.0
- reg:
Permanent drop (Reg). Default: 0.0
- ta:
Controller time constant (Ta) (>0). Typical Value = 0. Default: 0.0
- tb:
Gate servo time constant (Tb) (>0). Typical Value = 0. Default: 0.0
- treg:
Speed detector time constant (Treg). Default: 0.0
- tw:
Water inertia time constant (Tw) (>0). Typical Value = 0. Default: 0.0
- velmax:
Maximum gate opening velocity (Velmax). Unit = PU/sec. Typical Value = 0. Default: 0.0
- velmin:
Maximum gate closing velocity (Velmin). Unit = PU/sec. Typical Value = 0. Default: 0.0
Documentation of parent class TurbineGovernorDynamics:
Turbine-governor function block whose behavior is described by reference to a standard model
- AsynchronousMachineDynamics:
Asynchronous machine model with which this turbine-governor model is associated. Default: None
- SynchronousMachineDynamics:
Turbine-governor model associated with this synchronous machine model. Default: “list”
- TurbineLoadControllerDynamics:
Turbine load controller providing input to this turbine-governor. Default: None
Documentation of parent class DynamicsFunctionBlock:
Abstract parent class for all Dynamics function blocks.
- enabled:
Function block used indicator. true = use of function block is enabled false = use of function block is disabled. Default: False
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’