cimpy.cgmes_v2_4_15.Substation module
- class cimpy.cgmes_v2_4_15.Substation.Substation(DCConverterUnit='list', Region=None, VoltageLevels='list', *args, **kw_args)[source]
A collection of equipment for purposes other than generation or utilization, through which electric energy in bulk is passed for the purposes of switching or modifying its characteristics.
- DCConverterUnit:
Default: “list”
- Region:
The SubGeographicalRegion containing the substation. Default: None
- VoltageLevels:
The voltage levels within this substation. Default: “list”
Documentation of parent class EquipmentContainer:
A modeling construct to provide a root class for containing equipment.
- Equipments:
Contained equipment. Default: “list”
Documentation of parent class ConnectivityNodeContainer:
A base class for all objects that may contain connectivity nodes or topological nodes.
- ConnectivityNodes:
Connectivity nodes which belong to this connectivity node container. Default: “list”
- TopologicalNode:
The topological nodes which belong to this connectivity node container. Default: “list”
Documentation of parent class PowerSystemResource:
A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.
- Controls:
Regulating device governed by this control output. Default: “list”
- Location:
Location of this power system resource. Default: None
- Measurements:
The power system resource that contains the measurement. Default: “list”
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName: