cimpy.cgmes_v2_4_15.ExcPIC module
- class cimpy.cgmes_v2_4_15.ExcPIC.ExcPIC(e1=0.0, e2=0.0, efdmax=0.0, efdmin=0.0, ka=0.0, kc=0.0, ke=0.0, kf=0.0, ki=0.0, kp=0.0, se1=0.0, se2=0.0, ta1=0.0, ta2=0.0, ta3=0.0, ta4=0.0, te=0.0, tf1=0.0, tf2=0.0, vr1=0.0, vr2=0.0, vrmax=0.0, vrmin=0.0, *args, **kw_args)[source]
Proportional/Integral Regulator Excitation System Model. This model can be used to represent excitation systems with a proportional-integral (PI) voltage regulator controller.
- e1:
Field voltage value 1 (E1). Typical Value = 0. Default: 0.0
- e2:
Field voltage value 2 (E2). Typical Value = 0. Default: 0.0
- efdmax:
Exciter maximum limit (Efdmax). Typical Value = 8. Default: 0.0
- efdmin:
Exciter minimum limit (Efdmin). Typical Value = -0.87. Default: 0.0
- ka:
PI controller gain (Ka). Typical Value = 3.15. Default: 0.0
- kc:
Exciter regulation factor (Kc). Typical Value = 0.08. Default: 0.0
- ke:
Exciter constant (Ke). Typical Value = 0. Default: 0.0
- kf:
Rate feedback gain (Kf). Typical Value = 0. Default: 0.0
- ki:
Current source gain (Ki). Typical Value = 0. Default: 0.0
- kp:
Potential source gain (Kp). Typical Value = 6.5. Default: 0.0
- se1:
Saturation factor at E1 (Se1). Typical Value = 0. Default: 0.0
- se2:
Saturation factor at E2 (Se2). Typical Value = 0. Default: 0.0
- ta1:
PI controller time constant (Ta1). Typical Value = 1. Default: 0.0
- ta2:
Voltage regulator time constant (Ta2). Typical Value = 0.01. Default: 0.0
- ta3:
Lead time constant (Ta3). Typical Value = 0. Default: 0.0
- ta4:
Lag time constant (Ta4). Typical Value = 0. Default: 0.0
- te:
Exciter time constant (Te). Typical Value = 0. Default: 0.0
- tf1:
Rate feedback time constant (Tf1). Typical Value = 0. Default: 0.0
- tf2:
Rate feedback lag time constant (Tf2). Typical Value = 0. Default: 0.0
- vr1:
PI maximum limit (Vr1). Typical Value = 1. Default: 0.0
- vr2:
PI minimum limit (Vr2). Typical Value = -0.87. Default: 0.0
- vrmax:
Voltage regulator maximum limit (Vrmax). Typical Value = 1. Default: 0.0
- vrmin:
Voltage regulator minimum limit (Vrmin). Typical Value = -0.87. Default: 0.0
Documentation of parent class ExcitationSystemDynamics:
Excitation system function block whose behavior is described by reference to a standard model
- DiscontinuousExcitationControlDynamics:
Discontinuous excitation control model associated with this excitation system model. Default: None
- OverexcitationLimiterDynamics:
Overexcitation limiter model associated with this excitation system model. Default: None
- PFVArControllerType1Dynamics:
Power Factor or VAr controller Type I model associated with this excitation system model. Default: None
- PFVArControllerType2Dynamics:
Power Factor or VAr controller Type II model associated with this excitation system model. Default: None
- PowerSystemStabilizerDynamics:
Power system stabilizer model associated with this excitation system model. Default: None
- SynchronousMachineDynamics:
Synchronous machine model with which this excitation system model is associated. Default: None
- UnderexcitationLimiterDynamics:
Undrexcitation limiter model associated with this excitation system model. Default: None
- VoltageCompensatorDynamics:
Voltage compensator model associated with this excitation system model. Default: None
Documentation of parent class DynamicsFunctionBlock:
Abstract parent class for all Dynamics function blocks.
- enabled:
Function block used indicator. true = use of function block is enabled false = use of function block is disabled. Default: False
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’