cimpy.cgmes_v2_4_15.TapChangerControl module

class cimpy.cgmes_v2_4_15.TapChangerControl.TapChangerControl(TapChanger='list', *args, **kw_args)[source]

Describes behavior specific to tap changers, e.g. how the voltage at the end of a line varies with the load level and compensation of the voltage drop by tap adjustment.

TapChanger:

The regulating control scheme in which this tap changer participates. Default: “list”

Documentation of parent class RegulatingControl:

Specifies a set of equipment that works together to control a power system quantity such as voltage or flow. Remote bus voltage control is possible by specifying the controlled terminal located at some place remote from the controlling equipment. In case multiple equipment, possibly of different types, control same terminal there must be only one RegulatingControl at that terminal. The most specific subtype of RegulatingControl shall be used in case such equipment participate in the control, e.g. TapChangerControl for tap changers. For flow control load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment.

RegulatingCondEq:

The equipment that participates in this regulating control scheme. Default: “list”

RegulationSchedule:

Schedule for this Regulating regulating control. Default: “list”

Terminal:

The controls regulating this terminal. Default: None

discrete:

The regulation is performed in a discrete mode. This applies to equipment with discrete controls, e.g. tap changers and shunt compensators. Default: False

enabled:

The flag tells if regulation is enabled. Default: False

mode:

The regulating control mode presently available. This specification allows for determining the kind of regulation without need for obtaining the units from a schedule. Default: None

targetDeadband:

This is a deadband used with discrete control to avoid excessive update of controls like tap changers and shunt compensator banks while regulating. The units of those appropriate for the mode. Default: 0.0

targetValue:

The target value specified for case input. This value can be used for the target value without the use of schedules. The value has the units appropriate to the mode attribute. Default: 0.0

targetValueUnitMultiplier:

Specify the multiplier for used for the targetValue. Default: None

Documentation of parent class PowerSystemResource:

A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.

Controls:

Regulating device governed by this control output. Default: “list”

Location:

Location of this power system resource. Default: None

Measurements:

The power system resource that contains the measurement. Default: “list”

Documentation of parent class IdentifiedObject:

This is a root class to provide common identification for all classes needing identification and naming attributes.

DiagramObjects:

The domain object to which this diagram object is associated. Default: “list”

description:

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’

energyIdentCodeEic:

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’

mRID:

Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’

name:

The name is any free human readable and possibly non unique text naming the object. Default: ‘’

shortName:

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’

Inheritance Diagram:

Inheritance diagram of cimpy.cgmes_v2_4_15.TapChangerControl