cimpy.cgmes_v2_4_15.RemoteInputSignal module
- class cimpy.cgmes_v2_4_15.RemoteInputSignal.RemoteInputSignal(DiscontinuousExcitationControlDynamics=None, PFVArControllerType1Dynamics=None, PowerSystemStabilizerDynamics=None, Terminal=None, UnderexcitationLimiterDynamics=None, VoltageCompensatorDynamics=None, WindPlantDynamics=None, WindTurbineType1or2Dynamics=None, WindTurbineType3or4Dynamics=None, remoteSignalType=None, *args, **kw_args)[source]
Supports connection to a terminal associated with a remote bus from which an input signal of a specific type is coming.
- DiscontinuousExcitationControlDynamics:
Discontinuous excitation control model using this remote input signal. Default: None
- PFVArControllerType1Dynamics:
Power Factor or VAr controller Type I model using this remote input signal. Default: None
- PowerSystemStabilizerDynamics:
Power system stabilizer model using this remote input signal. Default: None
- Terminal:
Remote terminal with which this input signal is associated. Default: None
- UnderexcitationLimiterDynamics:
Underexcitation limiter model using this remote input signal. Default: None
- VoltageCompensatorDynamics:
Voltage compensator model using this remote input signal. Default: None
- WindPlantDynamics:
The remote signal with which this power plant is associated. Default: None
- WindTurbineType1or2Dynamics:
Wind generator Type 1 or Type 2 model using this remote input signal. Default: None
- WindTurbineType3or4Dynamics:
Remote input signal used by these wind turbine Type 3 or 4 models. Default: None
- remoteSignalType:
Type of input signal. Default: None
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’