cimpy.cgmes_v2_4_15.Command module

class cimpy.cgmes_v2_4_15.Command.Command(DiscreteValue=None, ValueAliasSet=None, normalValue=0, value=0, *args, **kw_args)[source]

A Command is a discrete control used for supervisory control.

DiscreteValue:

The Control variable associated with the MeasurementValue. Default: None

ValueAliasSet:

The ValueAliasSet used for translation of a Control value to a name. Default: None

normalValue:

Normal value for Control.value e.g. used for percentage scaling. Default: 0

value:

The value representing the actuator output. Default: 0

Documentation of parent class Control:

Control is used for supervisory/device control. It represents control outputs that are used to change the state in a process, e.g. close or open breaker, a set point value or a raise lower command.

PowerSystemResource:

The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator. Default: None

controlType:

Specifies the type of Control, e.g. BreakerOn/Off, GeneratorVoltageSetPoint, TieLineFlow etc. The ControlType.name shall be unique among all specified types and describe the type. Default: ‘’

operationInProgress:

Indicates that a client is currently sending control commands that has not completed. Default: False

timeStamp:

The last time a control output was sent. Default: ‘’

unitMultiplier:

The unit multiplier of the controlled quantity. Default: None

unitSymbol:

The unit of measure of the controlled quantity. Default: None

Documentation of parent class IdentifiedObject:

This is a root class to provide common identification for all classes needing identification and naming attributes.

DiagramObjects:

The domain object to which this diagram object is associated. Default: “list”

description:

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’

energyIdentCodeEic:

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’

mRID:

Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’

name:

The name is any free human readable and possibly non unique text naming the object. Default: ‘’

shortName:

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’

Inheritance Diagram: