cimpy.cgmes_v2_4_15.PFVArType2IEEEVArController module
- class cimpy.cgmes_v2_4_15.PFVArType2IEEEVArController.PFVArType2IEEEVArController(exlon=False, ki=0.0, kp=0.0, qref=0.0, vclmt=0.0, vref=0.0, vs=0.0, *args, **kw_args)[source]
The class represents IEEE VAR Controller Type 2 which is a summing point type controller. It makes up the outside loop of a two-loop system. This controller is implemented as a slow PI type controller, and the voltage regulator forms the inner loop and is implemented as a fast controller. Reference: IEEE Standard 421.5-2005 Section 11.5.
- exlon:
Overexcitation or under excitation flag () true = 1 (not in the overexcitation or underexcitation state, integral action is active) false = 0 (in the overexcitation or underexcitation state, so integral action is disabled to allow the limiter to play its role). Default: False
- ki:
Integral gain of the pf controller (). Default: 0.0
- kp:
Proportional gain of the pf controller (). Default: 0.0
- qref:
Reactive power reference (). Default: 0.0
- vclmt:
Maximum output of the pf controller (). Default: 0.0
- vref:
Voltage regulator reference (). Default: 0.0
- vs:
Generator sensing voltage (). Default: 0.0
Documentation of parent class PFVArControllerType2Dynamics:
Power Factor or VAr controller Type II function block whose behaviour is described by reference to a standard model
- ExcitationSystemDynamics:
Excitation system model with which this Power Factor or VAr controller Type II is associated. Default: None
Documentation of parent class DynamicsFunctionBlock:
Abstract parent class for all Dynamics function blocks.
- enabled:
Function block used indicator. true = use of function block is enabled false = use of function block is disabled. Default: False
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’