cimpy.cgmes_v2_4_15.DCLineSegment module
- class cimpy.cgmes_v2_4_15.DCLineSegment.DCLineSegment(PerLengthParameter=None, capacitance=0.0, inductance=0.0, length=0.0, resistance=0.0, *args, **kw_args)[source]
A wire or combination of wires not insulated from one another, with consistent electrical characteristics, used to carry direct current between points in the DC region of the power system.
- PerLengthParameter:
Set of per-length parameters for this line segment. Default: None
- capacitance:
Capacitance of the DC line segment. Significant for cables only. Default: 0.0
- inductance:
Inductance of the DC line segment. Neglectable compared with DCSeriesDevice used for smoothing. Default: 0.0
- length:
Segment length for calculating line section capabilities. Default: 0.0
- resistance:
Resistance of the DC line segment. Default: 0.0
Documentation of parent class DCConductingEquipment:
The parts of the DC power system that are designed to carry current or that are conductively connected through DC terminals.
- DCTerminals:
Default: “list”
Documentation of parent class Equipment:
The parts of a power system that are physical devices, electronic or mechanical.
- EquipmentContainer:
Container of this equipment. Default: None
- OperationalLimitSet:
The operational limit sets associated with this equipment. Default: “list”
- aggregate:
The single instance of equipment represents multiple pieces of equipment that have been modeled together as an aggregate. Examples would be power transformers or synchronous machines operating in parallel modeled as a single aggregate power transformer or aggregate synchronous machine. This is not to be used to indicate equipment that is part of a group of interdependent equipment produced by a network production program. Default: False
Documentation of parent class PowerSystemResource:
A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.
- Controls:
Regulating device governed by this control output. Default: “list”
- Location:
Location of this power system resource. Default: None
- Measurements:
The power system resource that contains the measurement. Default: “list”
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’