- class cimpy.cgmes_v2_4_15.DCConverterUnit.DCConverterUnit(Substation=None, operationMode=None, *args, **kw_args)[source]
Indivisible operative unit comprising all equipment between the point of common coupling on the AC side and the point of common coupling - DC side, essentially one or more converters, together with one or more converter transformers, converter control equipment, essential protective and switching devices and auxiliaries, if any, used for conversion.
- Substation:
Default: None
- operationMode:
Default: None
Documentation of parent class DCEquipmentContainer:
A modeling construct to provide a root class for containment of DC as well as AC equipment. The class differ from the EquipmentContaner for AC in that it may also contain DCNodes. Hence it can contain both AC and DC equipment.
- DCNodes:
Default: “list”
- DCTopologicalNode:
Default: “list”
Documentation of parent class EquipmentContainer:
A modeling construct to provide a root class for containing equipment.
- Equipments:
Contained equipment. Default: “list”
Documentation of parent class ConnectivityNodeContainer:
A base class for all objects that may contain connectivity nodes or topological nodes.
- ConnectivityNodes:
Connectivity nodes which belong to this connectivity node container. Default: “list”
- TopologicalNode:
The topological nodes which belong to this connectivity node container. Default: “list”
Documentation of parent class PowerSystemResource:
A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.
- Controls:
Regulating device governed by this control output. Default: “list”
- Location:
Location of this power system resource. Default: None
- Measurements:
The power system resource that contains the measurement. Default: “list”
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’