cimpy.cgmes_v2_4_15.WindGenType4IEC module
- class cimpy.cgmes_v2_4_15.WindGenType4IEC.WindGenType4IEC(dipmax=0.0, diqmax=0.0, diqmin=0.0, tg=0.0, *args, **kw_args)[source]
IEC Type 4 generator set model. Reference: IEC Standard 61400-27-1 Section 6.6.3.4.
- dipmax:
Maximum active current ramp rate (di). It is project dependent parameter. Default: 0.0
- diqmax:
Maximum reactive current ramp rate (di). It is project dependent parameter. Default: 0.0
- diqmin:
Minimum reactive current ramp rate (d). It is case dependent parameter. Default: 0.0
- tg:
Time constant (T). It is type dependent parameter. Default: 0.0
Documentation of parent class WindTurbineType3or4IEC:
Parent class supporting relationships to IEC wind turbines Type 3 and 4 and wind plant including their control models.
- WIndContQIEC:
Wind control Q model associated with this wind turbine type 3 or 4 model. Default: None
- WindContCurrLimIEC:
Wind control current limitation model associated with this wind turbine type 3 or 4 model. Default: None
- WindProtectionIEC:
Wind turbune protection model associated with this wind generator type 3 or 4 model. Default: None
Documentation of parent class WindTurbineType3or4Dynamics:
Parent class supporting relationships to wind turbines Type 3 and 4 and wind plant including their control models.
- EnergySource:
Energy Source (current source) with which this wind Type 3 or 4 dynamics model is asoociated. Default: None
- RemoteInputSignal:
Wind turbine Type 3 or 4 models using this remote input signal. Default: None
- WindPlantDynamics:
The wind plant with which the wind turbines type 3 or 4 are associated. Default: None
Documentation of parent class DynamicsFunctionBlock:
Abstract parent class for all Dynamics function blocks.
- enabled:
Function block used indicator. true = use of function block is enabled false = use of function block is disabled. Default: False
Documentation of parent class IdentifiedObject:
This is a root class to provide common identification for all classes needing identification and naming attributes.
- DiagramObjects:
The domain object to which this diagram object is associated. Default: “list”
- description:
The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’
- energyIdentCodeEic:
The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’
- mRID:
Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’
- name:
The name is any free human readable and possibly non unique text naming the object. Default: ‘’
- shortName:
The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’