cimpy.cgmes_v2_4_15.UnderexcLim2Simplified module

class cimpy.cgmes_v2_4_15.UnderexcLim2Simplified.UnderexcLim2Simplified(q0=0.0, q1=0.0, p0=0.0, p1=0.0, kui=0.0, vuimin=0.0, vuimax=0.0, *args, **kw_args)[source]

This model can be derived from UnderexcLimIEEE2. The limit characteristic (look -up table) is a single straight-line, the same as UnderexcLimIEEE2 (see Figure 10.4 (p 32), IEEE 421.5-2005 Section 10.2).

q0

Segment Q initial point (Q0). Typical Value = -0.31. Default: 0.0

q1

Segment Q end point (Q1). Typical Value = -0.1. Default: 0.0

p0

Segment P initial point (P0). Typical Value = 0. Default: 0.0

p1

Segment P end point (P1). Typical Value = 1. Default: 0.0

kui

Gain Under excitation limiter (Kui). Typical Value = 0.1. Default: 0.0

vuimin

Minimum error signal (V). Typical Value = 0. Default: 0.0

vuimax

Maximum error signal (V). Typical Value = 1. Default: 0.0

Documentation of parent class UnderexcitationLimiterDynamics:

Underexcitation limiter function block whose behaviour is described by reference to a standard model

RemoteInputSignal

Remote input signal used by this underexcitation limiter model. Default: None

ExcitationSystemDynamics

Excitation system model with which this underexcitation limiter model is associated. Default: None

Documentation of parent class DynamicsFunctionBlock:

Abstract parent class for all Dynamics function blocks.

enabled

Function block used indicator. true = use of function block is enabled false = use of function block is disabled. Default: False

Documentation of parent class IdentifiedObject:

This is a root class to provide common identification for all classes needing identification and naming attributes.

DiagramObjects

The domain object to which this diagram object is associated. Default: “list”

mRID

Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’

name

The name is any free human readable and possibly non unique text naming the object. Default: ‘’

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’

energyIdentCodeEic

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’

shortName

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’

cgmesProfile

alias of Profile

Inheritance Diagram:

Inheritance diagram of cimpy.cgmes_v2_4_15.UnderexcLim2Simplified