cimpy.cgmes_v2_4_15.EquivalentNetwork module

class cimpy.cgmes_v2_4_15.EquivalentNetwork.EquivalentNetwork(EquivalentEquipments='list', *args, **kw_args)[source]

A class that represents an external meshed network that has been reduced to an electrically equivalent model. The ConnectivityNodes contained in the equivalent are intended to reflect internal nodes of the equivalent. The boundary Connectivity nodes where the equivalent connects outside itself are NOT contained by the equivalent.

EquivalentEquipments

The equivalent where the reduced model belongs. Default: “list”

Documentation of parent class ConnectivityNodeContainer:

A base class for all objects that may contain connectivity nodes or topological nodes.

ConnectivityNodes

Connectivity nodes which belong to this connectivity node container. Default: “list”

TopologicalNode

The topological nodes which belong to this connectivity node container. Default: “list”

Documentation of parent class PowerSystemResource:

A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.

Controls

Regulating device governed by this control output. Default: “list”

Measurements

The power system resource that contains the measurement. Default: “list”

Location

Location of this power system resource. Default: None

Documentation of parent class IdentifiedObject:

This is a root class to provide common identification for all classes needing identification and naming attributes.

DiagramObjects

The domain object to which this diagram object is associated. Default: “list”

mRID

Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’

name

The name is any free human readable and possibly non unique text naming the object. Default: ‘’

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’

energyIdentCodeEic

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’

shortName

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’

cgmesProfile

alias of Profile

Inheritance Diagram:

Inheritance diagram of cimpy.cgmes_v2_4_15.EquivalentNetwork