cimpy.cgmes_v2_4_15.Substation module

class cimpy.cgmes_v2_4_15.Substation.Substation(DCConverterUnit='list', Region=None, VoltageLevels='list', *args, **kw_args)[source]

A collection of equipment for purposes other than generation or utilization, through which electric energy in bulk is passed for the purposes of switching or modifying its characteristics.

DCConverterUnit

Default: “list”

Region

The SubGeographicalRegion containing the substation. Default: None

VoltageLevels

The voltage levels within this substation. Default: “list”

Documentation of parent class EquipmentContainer:

A modeling construct to provide a root class for containing equipment.

Equipments

Contained equipment. Default: “list”

Documentation of parent class ConnectivityNodeContainer:

A base class for all objects that may contain connectivity nodes or topological nodes.

ConnectivityNodes

Connectivity nodes which belong to this connectivity node container. Default: “list”

TopologicalNode

The topological nodes which belong to this connectivity node container. Default: “list”

Documentation of parent class PowerSystemResource:

A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.

Controls

Regulating device governed by this control output. Default: “list”

Measurements

The power system resource that contains the measurement. Default: “list”

Location

Location of this power system resource. Default: None

Documentation of parent class IdentifiedObject:

This is a root class to provide common identification for all classes needing identification and naming attributes.

DiagramObjects

The domain object to which this diagram object is associated. Default: “list”

mRID

Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’

name

The name is any free human readable and possibly non unique text naming the object. Default: ‘’

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’

energyIdentCodeEic

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’

shortName

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’

cgmesProfile

alias of Profile

Inheritance Diagram:

Inheritance diagram of cimpy.cgmes_v2_4_15.Substation