cimpy.cgmes_v2_4_15.ControlArea module

class cimpy.cgmes_v2_4_15.ControlArea.ControlArea(type=None, TieFlow='list', ControlAreaGeneratingUnit='list', EnergyArea=None, netInterchange=0.0, pTolerance=0.0, *args, **kw_args)[source]

A control areais a grouping of generating units and/or loads and a cutset of tie lines (as terminals) which may be used for a variety of purposes including automatic generation control, powerflow solution area interchange control specification, and input to load forecasting. Note that any number of overlapping control area specifications can be superimposed on the physical model.

type

The primary type of control area definition used to determine if this is used for automatic generation control, for planning interchange control, or other purposes. A control area specified with primary type of automatic generation control could still be forecast and used as an interchange area in power flow analysis. Default: None

TieFlow

The tie flows associated with the control area. Default: “list”

ControlAreaGeneratingUnit

The generating unit specificaitons for the control area. Default: “list”

EnergyArea

The energy area that is forecast from this control area specification. Default: None

netInterchange

The specified positive net interchange into the control area, i.e. positive sign means flow in to the area. Default: 0.0

pTolerance

Active power net interchange tolerance Default: 0.0

Documentation of parent class PowerSystemResource:

A power system resource can be an item of equipment such as a switch, an equipment container containing many individual items of equipment such as a substation, or an organisational entity such as sub-control area. Power system resources can have measurements associated.

Controls

Regulating device governed by this control output. Default: “list”

Measurements

The power system resource that contains the measurement. Default: “list”

Location

Location of this power system resource. Default: None

Documentation of parent class IdentifiedObject:

This is a root class to provide common identification for all classes needing identification and naming attributes.

DiagramObjects

The domain object to which this diagram object is associated. Default: “list”

mRID

Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’

name

The name is any free human readable and possibly non unique text naming the object. Default: ‘’

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’

energyIdentCodeEic

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’

shortName

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’

cgmesProfile

alias of Profile

Inheritance Diagram:

Inheritance diagram of cimpy.cgmes_v2_4_15.ControlArea