cimpy.cgmes_v2_4_15.SvPowerFlow module

class cimpy.cgmes_v2_4_15.SvPowerFlow.SvPowerFlow(Terminal=None, p=0.0, q=0.0)[source]

State variable for power flow. Load convention is used for flow direction. This means flow out from the TopologicalNode into the equipment is positive.

Terminal

The terminal associated with the power flow state variable. Default: None

P

The active power flow. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment. Default: 0.0

Q

The reactive power flow. Load sign convention is used, i.e. positive sign means flow out from a TopologicalNode (bus) into the conducting equipment. Default: 0.0

cgmesProfile

alias of Profile