cimpy.cgmes_v2_4_15.RemoteInputSignal module

class cimpy.cgmes_v2_4_15.RemoteInputSignal.RemoteInputSignal(Terminal=None, remoteSignalType=None, PFVArControllerType1Dynamics=None, UnderexcitationLimiterDynamics=None, WindTurbineType1or2Dynamics=None, VoltageCompensatorDynamics=None, PowerSystemStabilizerDynamics=None, DiscontinuousExcitationControlDynamics=None, WindTurbineType3or4Dynamics=None, WindPlantDynamics=None, *args, **kw_args)[source]

Supports connection to a terminal associated with a remote bus from which an input signal of a specific type is coming.

Terminal

Remote terminal with which this input signal is associated. Default: None

remoteSignalType

Type of input signal. Default: None

PFVArControllerType1Dynamics

Power Factor or VAr controller Type I model using this remote input signal. Default: None

UnderexcitationLimiterDynamics

Underexcitation limiter model using this remote input signal. Default: None

WindTurbineType1or2Dynamics

Wind generator Type 1 or Type 2 model using this remote input signal. Default: None

VoltageCompensatorDynamics

Voltage compensator model using this remote input signal. Default: None

PowerSystemStabilizerDynamics

Power system stabilizer model using this remote input signal. Default: None

DiscontinuousExcitationControlDynamics

Discontinuous excitation control model using this remote input signal. Default: None

WindTurbineType3or4Dynamics

Remote input signal used by these wind turbine Type 3 or 4 models. Default: None

WindPlantDynamics

The remote signal with which this power plant is associated. Default: None

Documentation of parent class IdentifiedObject:

This is a root class to provide common identification for all classes needing identification and naming attributes.

DiagramObjects

The domain object to which this diagram object is associated. Default: “list”

mRID

Master resource identifier issued by a model authority. The mRID is globally unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552 Edition 1, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: ‘’

name

The name is any free human readable and possibly non unique text naming the object. Default: ‘’

description

The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: ‘’

energyIdentCodeEic

The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. References: Default: ‘’

shortName

The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: ‘’

cgmesProfile

alias of Profile

Inheritance Diagram:

Inheritance diagram of cimpy.cgmes_v2_4_15.RemoteInputSignal