|
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const CIMPP::BaseClassDefiner | declare () |
|
|
CIMPP::Frequency | db1 |
| | Intentional deadband width (db1). Unit = Hz. Typical value = 0. Default: 0.0.
|
|
CIMPP::ActivePower | db2 |
| | Unintentional deadband (db2). Unit = MW. Typical value = 0. Default: 0.0.
|
|
CIMPP::Frequency | eps |
| | Intentional db hysteresis (eps). Unit = Hz. Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | gv1 |
| | Nonlinear gain valve position point 1 (GV1). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | gv2 |
| | Nonlinear gain valve position point 2 (GV2). Typical value = 0,4. Default: 0.0.
|
|
CIMPP::PU | gv3 |
| | Nonlinear gain valve position point 3 (GV3). Typical value = 0,5. Default: 0.0.
|
|
CIMPP::PU | gv4 |
| | Nonlinear gain valve position point 4 (GV4). Typical value = 0,6. Default: 0.0.
|
|
CIMPP::PU | gv5 |
| | Nonlinear gain valve position point 5 (GV5). Typical value = 1. Default: 0.0.
|
|
CIMPP::PU | gv6 |
| | Nonlinear gain valve position point 6 (GV6). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | k |
| | Governor gain (reciprocal of droop) (K) (> 0). Typical value = 25. Default: 0.0.
|
|
CIMPP::Float | k1 |
| | Fraction of HP shaft power after first boiler pass (K1). Typical value = 0,2. Default: 0.0.
|
|
CIMPP::Float | k2 |
| | Fraction of LP shaft power after first boiler pass (K2). Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | k3 |
| | Fraction of HP shaft power after second boiler pass (K3). Typical value = 0,3. Default: 0.0.
|
|
CIMPP::Float | k4 |
| | Fraction of LP shaft power after second boiler pass (K4). Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | k5 |
| | Fraction of HP shaft power after third boiler pass (K5). Typical value = 0,5. Default: 0.0.
|
|
CIMPP::Float | k6 |
| | Fraction of LP shaft power after third boiler pass (K6). Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | k7 |
| | Fraction of HP shaft power after fourth boiler pass (K7). Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | k8 |
| | Fraction of LP shaft power after fourth boiler pass (K8). Typical value = 0. Default: 0.0.
|
|
CIMPP::ActivePower | mwbase |
| | Base for power values (MWbase) (> 0). Unit = MW. Default: 0.0.
|
|
CIMPP::PU | pgv1 |
| | Nonlinear gain power value point 1 (Pgv1). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | pgv2 |
| | Nonlinear gain power value point 2 (Pgv2). Typical value = 0,75. Default: 0.0.
|
|
CIMPP::PU | pgv3 |
| | Nonlinear gain power value point 3 (Pgv3). Typical value = 0,91. Default: 0.0.
|
|
CIMPP::PU | pgv4 |
| | Nonlinear gain power value point 4 (Pgv4). Typical value = 0,98. Default: 0.0.
|
|
CIMPP::PU | pgv5 |
| | Nonlinear gain power value point 5 (Pgv5). Typical value = 1. Default: 0.0.
|
|
CIMPP::PU | pgv6 |
| | Nonlinear gain power value point 6 (Pgv6). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | pmax |
| | Maximum valve opening (Pmax) (> GovSteam1.pmin). Typical value = 1. Default: 0.0.
|
|
CIMPP::PU | pmin |
| | Minimum valve opening (Pmin) (>= 0 and < GovSteam1.pmax). Typical value = 0. Default: 0.0.
|
|
CIMPP::Boolean | sdb1 |
| | Intentional deadband indicator. true = intentional deadband is applied false = intentional deadband is not applied. Typical value = true. Default: false.
|
|
CIMPP::Boolean | sdb2 |
| | Unintentional deadband location. true = intentional deadband is applied before point A false = intentional deadband is applied after point A. Typical value = true. Default: false.
|
|
CIMPP::Seconds | t1 |
| | Governor lag time constant (T1) (>= 0). Typical value = 0. Default: 0.0.
|
|
CIMPP::Seconds | t2 |
| | Governor lead time constant (T2) (>= 0). Typical value = 0. Default: 0.0.
|
|
CIMPP::Seconds | t3 |
| | Valve positioner time constant (T3) (> 0). Typical value = 0,1. Default: 0.0.
|
|
CIMPP::Seconds | t4 |
| | Inlet piping/steam bowl time constant (T4) (>= 0). Typical value = 0,3. Default: 0.0.
|
|
CIMPP::Seconds | t5 |
| | Time constant of second boiler pass (T5) (>= 0). Typical value = 5. Default: 0.0.
|
|
CIMPP::Seconds | t6 |
| | Time constant of third boiler pass (T6) (>= 0). Typical value = 0,5. Default: 0.0.
|
|
CIMPP::Seconds | t7 |
| | Time constant of fourth boiler pass (T7) (>= 0). Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | uc |
| | Maximum valve closing velocity (Uc) (< 0). Unit = PU / s. Typical value = -10. Default: 0.0.
|
|
CIMPP::Float | uo |
| | Maximum valve opening velocity (Uo) (> 0). Unit = PU / s. Typical value = 1. Default: 0.0.
|
|
CIMPP::Boolean | valve |
| | Nonlinear valve characteristic. true = nonlinear valve characteristic is used false = nonlinear valve characteristic is not used. Typical value = true. Default: false.
|
|
CIMPP::AsynchronousMachineDynamics * | AsynchronousMachineDynamics |
| | Asynchronous machine model with which this turbine-governor model is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics or to AsynchronousMachineDynamics. Default: nullptr.
|
|
CIMPP::SynchronousMachineDynamics * | SynchronousMachineDynamics |
| | Synchronous machine model with which this turbine-governor model is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics or to AsynchronousMachineDynamics. Default: nullptr.
|
|
CIMPP::TurbineLoadControllerDynamics * | TurbineLoadControllerDynamics |
| | Turbine load controller providing input to this turbine-governor. Default: nullptr.
|
|
CIMPP::Boolean | enabled |
| | Function block used indicator. true = use of function block is enabled false = use of function block is disabled. Default: false.
|
|
std::list< CIMPP::DiagramObject * > | DiagramObjects |
| | The diagram objects that are associated with the domain object. Default: {}.
|
|
CIMPP::String | description |
| | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: "".
|
|
CIMPP::String | energyIdentCodeEic |
| | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. Default: "".
|
|
CIMPP::String | mRID |
| | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: "".
|
|
CIMPP::String | name |
| | The name is any free human readable and possibly non unique text naming the object. Default: "".
|
|
CIMPP::String | shortName |
| | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: "".
|
Steam turbine governor, based on the GovSteamIEEE1 (with optional deadband and nonlinear valve gain added).