10#include <unordered_map>
12#include "TurbineGovernorDynamics.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
17#include "ActivePower.hpp"
20#include "Frequency.hpp"
28 class GovSteam1 :
public TurbineGovernorDynamics
33 ~GovSteam1()
override;
152 static const char debugName[];
153 const char* debugString()
const override;
155 const std::list<std::string>& getAttributeNames()
const override;
157 const std::string& getClassNamespaceUrl()
const override;
158 const std::string& getAttributeNamespaceUrl(
const std::string& attrName)
const override;
160 const std::list<CGMESProfile>& getPossibleProfiles()
const override;
161 const CGMESProfile& getRecommendedProfile()
const override;
162 const std::list<CGMESProfile>& getPossibleAttributeProfiles(
const std::string& attrName)
const override;
163 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes()
const override;
165 static void addConstructToMap(std::unordered_map<std::string,
BaseClass* (*)()>& factory_map);
166 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
167 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
168 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
169 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map)
const override;
170 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
172 bool isAssignableFrom(
BaseClass* otherObject)
const override;
176 std::map<std::string, AttrDetails> allAttrDetailsMap()
const override;
Definition BaseClass.hpp:22
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Definition ActivePower.hpp:14
Definition BaseClassDefiner.hpp:12
Definition Boolean.hpp:13
A floating point number. The range is unspecified and not limited.
Definition Float.hpp:14
Cycles per second.
Definition Frequency.hpp:14
CIMPP::Seconds t1
Governor lag time constant (T1) (>= 0). Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:123
CIMPP::PU gv1
Nonlinear gain valve position point 1 (GV1). Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:45
CIMPP::Boolean sdb2
Unintentional deadband location. true = intentional deadband is applied before point A false = intent...
Definition GovSteam1.hpp:120
CIMPP::PU k
Governor gain (reciprocal of droop) (K) (> 0). Typical value = 25. Default: 0.0.
Definition GovSteam1.hpp:63
CIMPP::Boolean valve
Nonlinear valve characteristic. true = nonlinear valve characteristic is used false = nonlinear valve...
Definition GovSteam1.hpp:150
CIMPP::Seconds t3
Valve positioner time constant (T3) (> 0). Typical value = 0,1. Default: 0.0.
Definition GovSteam1.hpp:129
CIMPP::Frequency db1
Intentional deadband width (db1). Unit = Hz. Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:36
CIMPP::Float k7
Fraction of HP shaft power after fourth boiler pass (K7). Typical value = 0. Default: 0....
Definition GovSteam1.hpp:84
CIMPP::PU pgv3
Nonlinear gain power value point 3 (Pgv3). Typical value = 0,91. Default: 0.0.
Definition GovSteam1.hpp:99
CIMPP::Frequency eps
Intentional db hysteresis (eps). Unit = Hz. Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:42
CIMPP::PU pgv5
Nonlinear gain power value point 5 (Pgv5). Typical value = 1. Default: 0.0.
Definition GovSteam1.hpp:105
CIMPP::Float k5
Fraction of HP shaft power after third boiler pass (K5). Typical value = 0,5. Default: 0....
Definition GovSteam1.hpp:78
CIMPP::Float uo
Maximum valve opening velocity (Uo) (> 0). Unit = PU / s. Typical value = 1. Default: 0....
Definition GovSteam1.hpp:147
CIMPP::PU gv2
Nonlinear gain valve position point 2 (GV2). Typical value = 0,4. Default: 0.0.
Definition GovSteam1.hpp:48
CIMPP::Seconds t7
Time constant of fourth boiler pass (T7) (>= 0). Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:141
CIMPP::Float uc
Maximum valve closing velocity (Uc) (< 0). Unit = PU / s. Typical value = -10. Default: 0....
Definition GovSteam1.hpp:144
CIMPP::ActivePower db2
Unintentional deadband (db2). Unit = MW. Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:39
CIMPP::PU pgv6
Nonlinear gain power value point 6 (Pgv6). Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:108
CIMPP::Seconds t5
Time constant of second boiler pass (T5) (>= 0). Typical value = 5. Default: 0.0.
Definition GovSteam1.hpp:135
CIMPP::PU pgv1
Nonlinear gain power value point 1 (Pgv1). Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:93
CIMPP::PU pmin
Minimum valve opening (Pmin) (>= 0 and < GovSteam1.pmax). Typical value = 0. Default: 0....
Definition GovSteam1.hpp:114
CIMPP::Float k8
Fraction of LP shaft power after fourth boiler pass (K8). Typical value = 0. Default: 0....
Definition GovSteam1.hpp:87
CIMPP::PU gv4
Nonlinear gain valve position point 4 (GV4). Typical value = 0,6. Default: 0.0.
Definition GovSteam1.hpp:54
CIMPP::ActivePower mwbase
Base for power values (MWbase) (> 0). Unit = MW. Default: 0.0.
Definition GovSteam1.hpp:90
CIMPP::PU pgv4
Nonlinear gain power value point 4 (Pgv4). Typical value = 0,98. Default: 0.0.
Definition GovSteam1.hpp:102
CIMPP::Float k4
Fraction of LP shaft power after second boiler pass (K4). Typical value = 0. Default: 0....
Definition GovSteam1.hpp:75
CIMPP::PU gv3
Nonlinear gain valve position point 3 (GV3). Typical value = 0,5. Default: 0.0.
Definition GovSteam1.hpp:51
CIMPP::Boolean sdb1
Intentional deadband indicator. true = intentional deadband is applied false = intentional deadband i...
Definition GovSteam1.hpp:117
CIMPP::Float k6
Fraction of LP shaft power after third boiler pass (K6). Typical value = 0. Default: 0....
Definition GovSteam1.hpp:81
CIMPP::PU pgv2
Nonlinear gain power value point 2 (Pgv2). Typical value = 0,75. Default: 0.0.
Definition GovSteam1.hpp:96
CIMPP::PU gv5
Nonlinear gain valve position point 5 (GV5). Typical value = 1. Default: 0.0.
Definition GovSteam1.hpp:57
CIMPP::Float k1
Fraction of HP shaft power after first boiler pass (K1). Typical value = 0,2. Default: 0....
Definition GovSteam1.hpp:66
CIMPP::PU gv6
Nonlinear gain valve position point 6 (GV6). Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:60
CIMPP::Seconds t2
Governor lead time constant (T2) (>= 0). Typical value = 0. Default: 0.0.
Definition GovSteam1.hpp:126
CIMPP::Float k3
Fraction of HP shaft power after second boiler pass (K3). Typical value = 0,3. Default: 0....
Definition GovSteam1.hpp:72
CIMPP::Seconds t4
Inlet piping/steam bowl time constant (T4) (>= 0). Typical value = 0,3. Default: 0....
Definition GovSteam1.hpp:132
CIMPP::Float k2
Fraction of LP shaft power after first boiler pass (K2). Typical value = 0. Default: 0....
Definition GovSteam1.hpp:69
CIMPP::PU pmax
Maximum valve opening (Pmax) (> GovSteam1.pmin). Typical value = 1. Default: 0.0.
Definition GovSteam1.hpp:111
CIMPP::Seconds t6
Time constant of third boiler pass (T6) (>= 0). Typical value = 0,5. Default: 0.0.
Definition GovSteam1.hpp:138
Per Unit - a positive or negative value referred to a defined base. Values typically range from -10 t...
Definition PU.hpp:14
Time, in seconds.
Definition Seconds.hpp:14