Hydro turbine and governor. Represents plants with straightforward penstock configurations and "three term" electro-hydraulic governors (i.e. WoodwardTM electronic). [Footnote: Woodward electronic governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].
More...
|
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const CIMPP::BaseClassDefiner | declare () |
|
|
CIMPP::PU | atw |
| | Factor multiplying Tw (Atw). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | d |
| | Turbine damping factor (D). Unit = delta P / delta speed. Typical value = 0. Default: 0.0.
|
|
CIMPP::Boolean | feedbackSignal |
| | Feedback signal type flag (Flag). true = use gate position feedback signal false = use Pe. Default: false.
|
|
CIMPP::PU | g0 |
| | Gate opening at speed no load (G0). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | g1 |
| | Intermediate gate opening (G1). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | g2 |
| | Intermediate gate opening (G2). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | gmax |
| | Maximum gate opening (Gmax) (> GovHydroPID2.gmin). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | gmin |
| | Minimum gate opening (Gmin) (> GovHydroPID2.gmax). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | kd |
| | Derivative gain (Kd). Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | ki |
| | Reset gain (Ki). Unit = PU/s. Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | kp |
| | Proportional gain (Kp). Typical value = 0. Default: 0.0.
|
|
CIMPP::ActivePower | mwbase |
| | Base for power values (MWbase) (>0). Unit = MW. Default: 0.0.
|
|
CIMPP::PU | p1 |
| | Power at gate opening G1 (P1). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | p2 |
| | Power at gate opening G2 (P2). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | p3 |
| | Power at full opened gate (P3). Typical value = 0. Default: 0.0.
|
|
CIMPP::PU | rperm |
| | Permanent drop (Rperm). Typical value = 0. Default: 0.0.
|
|
CIMPP::Seconds | ta |
| | Controller time constant (Ta) (>= 0). Typical value = 0. Default: 0.0.
|
|
CIMPP::Seconds | tb |
| | Gate servo time constant (Tb) (> 0). Default: 0.0.
|
|
CIMPP::Seconds | treg |
| | Speed detector time constant (Treg) (>= 0). Typical value = 0. Default: 0.0.
|
|
CIMPP::Seconds | tw |
| | Water inertia time constant (Tw) (>= 0). Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | velmax |
| | Maximum gate opening velocity (Velmax) (< GovHydroPID2.velmin). Unit = PU / s. Typical value = 0. Default: 0.0.
|
|
CIMPP::Float | velmin |
| | Maximum gate closing velocity (Velmin) (> GovHydroPID2.velmax). Unit = PU / s. Typical value = 0. Default: 0.0.
|
|
CIMPP::AsynchronousMachineDynamics * | AsynchronousMachineDynamics |
| | Asynchronous machine model with which this turbine-governor model is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics or to AsynchronousMachineDynamics. Default: nullptr.
|
|
CIMPP::SynchronousMachineDynamics * | SynchronousMachineDynamics |
| | Synchronous machine model with which this turbine-governor model is associated. TurbineGovernorDynamics shall have either an association to SynchronousMachineDynamics or to AsynchronousMachineDynamics. Default: nullptr.
|
|
CIMPP::TurbineLoadControllerDynamics * | TurbineLoadControllerDynamics |
| | Turbine load controller providing input to this turbine-governor. Default: nullptr.
|
|
CIMPP::Boolean | enabled |
| | Function block used indicator. true = use of function block is enabled false = use of function block is disabled. Default: false.
|
|
std::list< CIMPP::DiagramObject * > | DiagramObjects |
| | The diagram objects that are associated with the domain object. Default: {}.
|
|
CIMPP::String | description |
| | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: "".
|
|
CIMPP::String | energyIdentCodeEic |
| | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. Default: "".
|
|
CIMPP::String | mRID |
| | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: "".
|
|
CIMPP::String | name |
| | The name is any free human readable and possibly non unique text naming the object. Default: "".
|
|
CIMPP::String | shortName |
| | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: "".
|
Hydro turbine and governor. Represents plants with straightforward penstock configurations and "three term" electro-hydraulic governors (i.e. WoodwardTM electronic). [Footnote: Woodward electronic governors are an example of suitable products available commercially. This information is given for the convenience of users of this document and does not constitute an endorsement by IEC of these products.].