CGMES_3_0_0
Loading...
Searching...
No Matches
GovHydroPID2.hpp
1#ifndef GovHydroPID2_H
2#define GovHydroPID2_H
3/*
4Generated from the CGMES files via cimgen: https://github.com/sogno-platform/cimgen
5*/
6
7#include <list>
8#include <map>
9#include <string>
10#include <unordered_map>
11
12#include "TurbineGovernorDynamics.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
16
17#include "ActivePower.hpp"
18#include "Boolean.hpp"
19#include "Float.hpp"
20#include "PU.hpp"
21#include "Seconds.hpp"
22
23namespace CIMPP
24{
25
27 class GovHydroPID2 : public TurbineGovernorDynamics
28 {
29 public:
30 /* constructor initialising all attributes to null */
31 GovHydroPID2();
32 ~GovHydroPID2() override;
33
36
39
42
45
48
51
54
57
60
63
66
69
72
75
78
81
84
87
90
93
96
99
100 static const char debugName[];
101 const char* debugString() const override;
102
103 const std::list<std::string>& getAttributeNames() const override;
104
105 const std::string& getClassNamespaceUrl() const override;
106 const std::string& getAttributeNamespaceUrl(const std::string& attrName) const override;
107
108 const std::list<CGMESProfile>& getPossibleProfiles() const override;
109 const CGMESProfile& getRecommendedProfile() const override;
110 const std::list<CGMESProfile>& getPossibleAttributeProfiles(const std::string& attrName) const override;
111 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes() const override;
112
113 static void addConstructToMap(std::unordered_map<std::string, BaseClass* (*)()>& factory_map);
114 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
115 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
116 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map) const override;
117 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map) const override;
118 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map) const override;
119
120 bool isAssignableFrom(BaseClass* otherObject) const override;
121 static const BaseClassDefiner declare();
122
123 protected:
124 std::map<std::string, AttrDetails> allAttrDetailsMap() const override;
125 };
126
127 BaseClass* GovHydroPID2_factory();
128}
129#endif
Definition BaseClass.hpp:22
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Definition ActivePower.hpp:14
Definition BaseClassDefiner.hpp:12
Definition Boolean.hpp:13
A floating point number. The range is unspecified and not limited.
Definition Float.hpp:14
CIMPP::PU atw
Factor multiplying Tw (Atw). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:35
CIMPP::ActivePower mwbase
Base for power values (MWbase) (>0). Unit = MW. Default: 0.0.
Definition GovHydroPID2.hpp:68
CIMPP::PU kd
Derivative gain (Kd). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:59
CIMPP::PU p3
Power at full opened gate (P3). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:77
CIMPP::PU g1
Intermediate gate opening (G1). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:47
CIMPP::PU gmin
Minimum gate opening (Gmin) (> GovHydroPID2.gmax). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:56
CIMPP::PU p1
Power at gate opening G1 (P1). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:71
CIMPP::PU p2
Power at gate opening G2 (P2). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:74
CIMPP::Float velmin
Maximum gate closing velocity (Velmin) (> GovHydroPID2.velmax). Unit = PU / s. Typical value = 0....
Definition GovHydroPID2.hpp:98
CIMPP::Seconds tb
Gate servo time constant (Tb) (> 0). Default: 0.0.
Definition GovHydroPID2.hpp:86
CIMPP::Seconds tw
Water inertia time constant (Tw) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:92
CIMPP::Float ki
Reset gain (Ki). Unit = PU/s. Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:62
CIMPP::PU g2
Intermediate gate opening (G2). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:50
CIMPP::Float velmax
Maximum gate opening velocity (Velmax) (< GovHydroPID2.velmin). Unit = PU / s. Typical value = 0....
Definition GovHydroPID2.hpp:95
CIMPP::PU d
Turbine damping factor (D). Unit = delta P / delta speed. Typical value = 0. Default: 0....
Definition GovHydroPID2.hpp:38
CIMPP::PU g0
Gate opening at speed no load (G0). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:44
CIMPP::PU gmax
Maximum gate opening (Gmax) (> GovHydroPID2.gmin). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:53
CIMPP::Boolean feedbackSignal
Feedback signal type flag (Flag). true = use gate position feedback signal false = use Pe....
Definition GovHydroPID2.hpp:41
CIMPP::PU rperm
Permanent drop (Rperm). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:80
CIMPP::Seconds treg
Speed detector time constant (Treg) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:89
CIMPP::Seconds ta
Controller time constant (Ta) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:83
CIMPP::PU kp
Proportional gain (Kp). Typical value = 0. Default: 0.0.
Definition GovHydroPID2.hpp:65
Per Unit - a positive or negative value referred to a defined base. Values typically range from -10 t...
Definition PU.hpp:14
Time, in seconds.
Definition Seconds.hpp:14