A unit with valves for three phases, together with unit control equipment, essential protective and switching devices, DC storage capacitors, phase reactors and auxiliaries, if any, used for conversion.
More...
|
| const char * | debugString () const override |
| const std::list< std::string > & | getAttributeNames () const override |
| const std::string & | getClassNamespaceUrl () const override |
| const std::string & | getAttributeNamespaceUrl (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfiles () const override |
| const CGMESProfile & | getRecommendedProfile () const override |
| const std::list< CGMESProfile > & | getPossibleAttributeProfiles (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfilesIncludingAttributes () const override |
| void | addPrimitiveGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| void | addClassGetFnsToMap (std::map< std::string, class_get_function > &get_map) const override |
| void | addEnumGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| bool | isAssignableFrom (BaseClass *otherObject) const override |
| const char * | debugString () const override |
| const std::list< std::string > & | getAttributeNames () const override |
| const std::string & | getClassNamespaceUrl () const override |
| const std::string & | getAttributeNamespaceUrl (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfiles () const override |
| const CGMESProfile & | getRecommendedProfile () const override |
| const std::list< CGMESProfile > & | getPossibleAttributeProfiles (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfilesIncludingAttributes () const override |
| void | addPrimitiveGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| void | addClassGetFnsToMap (std::map< std::string, class_get_function > &get_map) const override |
| void | addEnumGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| bool | isAssignableFrom (BaseClass *otherObject) const override |
| const char * | debugString () const override |
| const std::list< std::string > & | getAttributeNames () const override |
| const std::string & | getClassNamespaceUrl () const override |
| const std::string & | getAttributeNamespaceUrl (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfiles () const override |
| const CGMESProfile & | getRecommendedProfile () const override |
| const std::list< CGMESProfile > & | getPossibleAttributeProfiles (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfilesIncludingAttributes () const override |
| void | addPrimitiveGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| void | addClassGetFnsToMap (std::map< std::string, class_get_function > &get_map) const override |
| void | addEnumGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| bool | isAssignableFrom (BaseClass *otherObject) const override |
| const char * | debugString () const override |
| const std::list< std::string > & | getAttributeNames () const override |
| const std::string & | getClassNamespaceUrl () const override |
| const std::string & | getAttributeNamespaceUrl (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfiles () const override |
| const CGMESProfile & | getRecommendedProfile () const override |
| const std::list< CGMESProfile > & | getPossibleAttributeProfiles (const std::string &attrName) const override |
| const std::list< CGMESProfile > & | getPossibleProfilesIncludingAttributes () const override |
| void | addPrimitiveGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| void | addClassGetFnsToMap (std::map< std::string, class_get_function > &get_map) const override |
| void | addEnumGetFnsToMap (std::map< std::string, get_function > &get_map) const override |
| bool | isAssignableFrom (BaseClass *otherObject) const override |
|
void | setRdfid (const std::string &id) |
|
std::string | getRdfid () const |
|
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const CIMPP::BaseClassDefiner | declare () |
|
|
std::list< CIMPP::ACDCConverterDCTerminal * > | DCTerminals |
| | A DC converter have DC converter terminals. A converter has two DC converter terminals. Default: {}.
|
|
CIMPP::Terminal * | PccTerminal |
| | Point of common coupling terminal for this converter DC side. It is typically the terminal on the power transformer (or switch) closest to the AC network. Default: nullptr.
|
|
CIMPP::ApparentPower | baseS |
| | Base apparent power of the converter pole. The attribute shall be a positive value. Default: 0.0.
|
| CIMPP::ActivePower | maxP |
| | Converter DC current, also called Id. It is converter`s state variable, result from power flow. Default: 0.0 */ CIMPP::CurrentFlow idc;.
|
| CIMPP::ActivePower | minP |
| | The maximum voltage on the DC side at which the converter should operate. It is converter`s configuration data used in power flow. The attribute shall be a positive value. Default: 0.0 */ CIMPP::Voltage maxUdc;.
|
| CIMPP::Integer | numberOfValves |
| | The minimum voltage on the DC side at which the converter should operate. It is converter`s configuration data used in power flow. The attribute shall be a positive value. Default: 0.0 */ CIMPP::Voltage minUdc;.
|
|
CIMPP::ActivePower | p |
| | Active power at the point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. Starting value for a steady state solution in the case a simplified power flow model is used. Default: 0.0.
|
| CIMPP::ReactivePower | q |
| | The active power loss at a DC Pole = idleLoss + switchingLoss*|Idc| + resitiveLoss*Idc^2. For lossless operation Pdc=Pac. For rectifier operation with losses Pdc=Pac-lossP. For inverter operation with losses Pdc=Pac+lossP. It is converter`s state variable used in power flow. The attribute shall be a positive value. Default: 0.0 */ CIMPP::ActivePower poleLossP;.
|
| CIMPP::ActivePowerPerCurrentFlow | switchingLoss |
| | Rated converter DC voltage, also called UdN. The attribute shall be a positive value. It is converter`s configuration data used in power flow. For instance a bipolar HVDC link with value 200 kV has a 400kV difference between the dc lines. Default: 0.0 */ CIMPP::Voltage ratedUdc;.
|
|
CIMPP::ActivePower | targetPpcc |
| | Real power injection target in AC grid, at point of common coupling. Load sign convention is used, i.e. positive sign means flow out from a node. Default: 0.0.
|
|
CIMPP::Voltage | targetUdc |
| | Target value for DC voltage magnitude. The attribute shall be a positive value. Default: 0.0.
|
| CIMPP::Voltage | valveU0 |
| | Line-to-line converter voltage, the voltage at the AC side of the valve. It is converter`s state variable, result from power flow. The attribute shall be a positive value. Default: 0.0 */ CIMPP::Voltage uc;.
|
|
CIMPP::BaseVoltage * | BaseVoltage |
| | Base voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers. Default: nullptr.
|
|
CIMPP::SvStatus * | SvStatus |
| | The status state variable associated with this conducting equipment. Default: nullptr.
|
|
std::list< CIMPP::Terminal * > | Terminals |
| | Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes. Default: {}.
|
|
CIMPP::EquipmentContainer * | EquipmentContainer |
| | Container of this equipment. Default: nullptr.
|
|
std::list< CIMPP::OperationalLimitSet * > | OperationalLimitSet |
| | The operational limit sets associated with this equipment. Default: {}.
|
|
CIMPP::Boolean | aggregate |
| | The aggregate flag provides an alternative way of representing an aggregated (equivalent) element. It is applicable in cases when the dedicated classes for equivalent equipment do not have all of the attributes necessary to represent the required level of detail. In case the flag is set to true the single instance of equipment represents multiple pieces of equipment that have been modelled together as an aggregate equivalent obtained by a network reduction procedure. Examples would be power transformers or synchronous machines operating in parallel modelled as a single aggregate power transformer or aggregate synchronous machine. The attribute is not used for EquivalentBranch, EquivalentShunt and EquivalentInjection. Default: false.
|
|
CIMPP::Boolean | inService |
| | Specifies the availability of the equipment. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model. Default: false.
|
|
CIMPP::Boolean | normallyInService |
| | Specifies the availability of the equipment under normal operating conditions. True means the equipment is available for topology processing, which determines if the equipment is energized or not. False means that the equipment is treated by network applications as if it is not in the model. Default: false.
|
|
std::list< CIMPP::Control * > | Controls |
| | The controller outputs used to actually govern a regulating device, e.g. the magnetization of a synchronous machine or capacitor bank breaker actuator. Default: {}.
|
|
CIMPP::Location * | Location |
| | Location of this power system resource. Default: nullptr.
|
|
std::list< CIMPP::Measurement * > | Measurements |
| | The measurements associated with this power system resource. Default: {}.
|
|
std::list< CIMPP::DiagramObject * > | DiagramObjects |
| | The diagram objects that are associated with the domain object. Default: {}.
|
|
CIMPP::String | description |
| | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: "".
|
|
CIMPP::String | energyIdentCodeEic |
| | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. Default: "".
|
|
CIMPP::String | mRID |
| | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: "".
|
|
CIMPP::String | name |
| | The name is any free human readable and possibly non unique text naming the object. Default: "".
|
|
CIMPP::String | shortName |
| | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: "".
|
A unit with valves for three phases, together with unit control equipment, essential protective and switching devices, DC storage capacitors, phase reactors and auxiliaries, if any, used for conversion.
Line-to-line converter voltage, the voltage at the AC side of the valve. It is converter`s state variable, result from power flow. The attribute shall be a positive value. Default: 0.0 */ CIMPP::Voltage uc;.
/** Converter voltage at the DC side, also called Ud. It is converter`s state variable, result from power flow. The attribute shall be a positive value. Default: 0.0 */ CIMPP::Voltage udc;
/** Valve threshold voltage, also called Uvalve. Forward voltage drop when the valve is conducting. Used in loss calculations, i.e. the switchLoss depend on numberOfValves * valveU0. Default: 0.0