Simplified plant voltage and reactive power control model for use with type 3 and type 4 wind turbine models. Reference: IEC 61400-27-1:2015, Annex D.
More...
|
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const CIMPP::BaseClassDefiner | declare () |
|
|
std::list< CIMPP::WindDynamicsLookupTable * > | WindDynamicsLookupTable |
| | The wind dynamics lookup table associated with this voltage and reactive power wind plant model. Default: {}.
|
|
CIMPP::WindPlantIEC * | WindPlantIEC |
| | Wind plant reactive control model associated with this wind plant. Default: nullptr.
|
|
CIMPP::PU | dxrefmax |
| | Maximum positive ramp rate for wind turbine reactive power/voltage reference (dxrefmax) (> WindPlantReactiveControlIEC.dxrefmin). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::PU | dxrefmin |
| | Maximum negative ramp rate for wind turbine reactive power/voltage reference (dxrefmin) (< WindPlantReactiveControlIEC.dxrefmax). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Float | kiwpx |
| | Plant Q controller integral gain (KIWPx). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::PU | kiwpxmax |
| | Maximum reactive power/voltage reference from integration (KIWPxmax) (> WindPlantReactiveControlIEC.kiwpxmin). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::PU | kiwpxmin |
| | Minimum reactive power/voltage reference from integration (KIWPxmin) (< WindPlantReactiveControlIEC.kiwpxmax). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Float | kpwpx |
| | Plant Q controller proportional gain (KPWPx). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::PU | kwpqref |
| | Reactive power reference gain (KWPqref). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::PU | kwpqu |
| | Plant voltage control droop (KWPqu). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Seconds | tuqfilt |
| | Filter time constant for voltage-dependent reactive power (Tuqfilt) (>= 0). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Seconds | twppfiltq |
| | Filter time constant for active power measurement (TWPpfiltq) (>= 0). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Seconds | twpqfiltq |
| | Filter time constant for reactive power measurement (TWPqfiltq) (>= 0). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Seconds | twpufiltq |
| | Filter time constant for voltage measurement (TWPufiltq) (>= 0). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Seconds | txft |
| | Lead time constant in reference value transfer function (Txft) (>= 0). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::Seconds | txfv |
| | Lag time constant in reference value transfer function (Txfv) (>= 0). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::PU | uwpqdip |
| | Voltage threshold for UVRT detection in Q control (uWPqdip). It is a project-dependent parameter. Default: 0.0.
|
|
CIMPP::WindPlantQcontrolModeKind | windPlantQcontrolModesType |
| | Reactive power/voltage controller mode (MWPqmode). It is a case-dependent parameter. Default: 0.
|
|
CIMPP::PU | xrefmax |
| | Maximum xWTref (qWTref or delta uWTref) request from the plant controller (xrefmax) (> WindPlantReactiveControlIEC.xrefmin). It is a case-dependent parameter. Default: 0.0.
|
|
CIMPP::PU | xrefmin |
| | Minimum xWTref (qWTref or delta uWTref) request from the plant controller (xrefmin) (< WindPlantReactiveControlIEC.xrefmax). It is a project-dependent parameter. Default: 0.0.
|
|
std::list< CIMPP::DiagramObject * > | DiagramObjects |
| | The diagram objects that are associated with the domain object. Default: {}.
|
|
CIMPP::String | description |
| | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: "".
|
|
CIMPP::String | energyIdentCodeEic |
| | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. Default: "".
|
|
CIMPP::String | mRID |
| | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: "".
|
|
CIMPP::String | name |
| | The name is any free human readable and possibly non unique text naming the object. Default: "".
|
|
CIMPP::String | shortName |
| | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: "".
|
Simplified plant voltage and reactive power control model for use with type 3 and type 4 wind turbine models. Reference: IEC 61400-27-1:2015, Annex D.