CIMPP::WindLookupTableFunctionKind Class Reference

Function of the lookup table. More...

#include <WindLookupTableFunctionKind.hpp>

Public Types

enum  WindLookupTableFunctionKind_ENUM {
  prr , omegap , ipmax , iqmax ,
  pwp , tcwdu , tduwt , qmaxp ,
  qminp , qmaxu , qminu , tuover ,
  tuunder , tfover , tfunder , qwp
}

Public Member Functions

 WindLookupTableFunctionKind (WindLookupTableFunctionKind_ENUM value)
WindLookupTableFunctionKind & operator= (WindLookupTableFunctionKind_ENUM rop)
 operator WindLookupTableFunctionKind_ENUM () const
const char * debugString () const

Public Attributes

WindLookupTableFunctionKind_ENUM value
bool initialized

Static Public Attributes

static const char debugName [] = "WindLookupTableFunctionKind"

Friends

std::istream & operator>> (std::istream &lop, WindLookupTableFunctionKind &rop)
std::ostream & operator<< (std::ostream &os, const WindLookupTableFunctionKind &obj)

Detailed Description

Function of the lookup table.

Member Enumeration Documentation

◆ WindLookupTableFunctionKind_ENUM

Enumerator
prr 

Power versus speed change (negative slip) lookup table (prr(deltaomega)). It is used for the rotor resistance control model, IEC 61400-27-1:2015, 5.6.5.3.

omegap 

Power vs. speed lookup table (omega(p)). It is used for the P control model type 3, IEC 61400-27-1:2015, 5.6.5.4.

ipmax 

Lookup table for voltage dependency of active current limits (ipmax(uWT)). It is used for the current limitation model, IEC 61400-27-1:2015, 5.6.5.8.

iqmax 

Lookup table for voltage dependency of reactive current limits (iqmax(uWT)). It is used for the current limitation model, IEC 61400-27-1:2015, 5.6.5.8.

pwp 

Power vs. frequency lookup table (pWPbias(f)). It is used for the wind power plant frequency and active power control model, IEC 61400-27-1:2015, Annex D.

tcwdu 

Crowbar duration versus voltage variation look-up table (TCW(du)). It is a case-dependent parameter. It is used for the type 3B generator set model, IEC 61400-27-1:2015, 5.6.3.3.

tduwt 

Lookup table to determine the duration of the power reduction after a voltage dip, depending on the size of the voltage dip (Td(uWT)). It is a type-dependent parameter. It is used for the pitch control power model, IEC 61400-27-1:2015, 5.6.5.1.

qmaxp 

Lookup table for active power dependency of reactive power maximum limit (qmaxp(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.

qminp 

Lookup table for active power dependency of reactive power minimum limit (qminp(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.

qmaxu 

Lookup table for voltage dependency of reactive power maximum limit (qmaxu(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.

qminu 

Lookup table for voltage dependency of reactive power minimum limit (qminu(p)). It is used for the QP and QU limitation model, IEC 61400-27-1:2015, 5.6.5.10.

tuover 

Disconnection time versus over-voltage lookup table (Tuover(uWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.

tuunder 

Disconnection time versus under-voltage lookup table (Tuunder(uWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.

tfover 

Disconnection time versus over-frequency lookup table (Tfover(fWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.

tfunder 

Disconnection time versus under-frequency lookup table (Tfunder(fWT)). It is used for the grid protection model, IEC 61400-27-1:2015, 5.6.6.

qwp 

Look up table for the UQ static mode (qWP(uerr)). It is used for the voltage and reactive power control model, IEC 61400-27-1:2015, Annex D.


The documentation for this class was generated from the following files: