A conducting connection point of a power transformer. It corresponds to a physical transformer winding terminal. In earlier CIM versions, the TransformerWinding class served a similar purpose, but this class is more flexible because it associates to terminal but is not a specialization of ConductingEquipment.
More...
#include <TransformerEnd.hpp>
|
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const BaseClassDefiner | declare () |
|
static void | addConstructToMap (std::unordered_map< std::string, BaseClass *(*)()> &factory_map) |
|
static void | addPrimitiveAssignFnsToMap (std::unordered_map< std::string, assign_function > &assign_map) |
|
static void | addClassAssignFnsToMap (std::unordered_map< std::string, class_assign_function > &assign_map) |
|
static const CIMPP::BaseClassDefiner | declare () |
|
|
CIMPP::BaseVoltage * | BaseVoltage |
| | Base voltage of the transformer end. This is essential for PU calculation. Default: nullptr.
|
|
CIMPP::PhaseTapChanger * | PhaseTapChanger |
| | Phase tap changer associated with this transformer end. Default: nullptr.
|
|
CIMPP::RatioTapChanger * | RatioTapChanger |
| | Ratio tap changer associated with this transformer end. Default: nullptr.
|
|
CIMPP::Terminal * | Terminal |
| | Terminal of the power transformer to which this transformer end belongs. Default: nullptr.
|
| CIMPP::Boolean | grounded |
| | Number for this transformer end, corresponding to the end`s order in the power transformer vector group or phase angle clock number. Highest voltage winding should be 1. Each end within a power transformer should have a unique subsequent end number. Note the transformer end number need not match the terminal sequence number. Default: 0 */ CIMPP::Integer endNumber;.
|
|
CIMPP::Resistance | rground |
| | (for Yn and Zn connections) Resistance part of neutral impedance where grounded is true. Default: 0.0
|
|
CIMPP::Reactance | xground |
| | (for Yn and Zn connections) Reactive part of neutral impedance where grounded is true. Default: 0.0
|
|
std::list< CIMPP::DiagramObject * > | DiagramObjects |
| | The diagram objects that are associated with the domain object. Default: {}.
|
|
CIMPP::String | description |
| | The description is a free human readable text describing or naming the object. It may be non unique and may not correlate to a naming hierarchy. Default: "".
|
|
CIMPP::String | energyIdentCodeEic |
| | The attribute is used for an exchange of the EIC code (Energy identification Code). The length of the string is 16 characters as defined by the EIC code. For details on EIC scheme please refer to ENTSO-E web site. Default: "".
|
|
CIMPP::String | mRID |
| | Master resource identifier issued by a model authority. The mRID is unique within an exchange context. Global uniqueness is easily achieved by using a UUID, as specified in RFC 4122, for the mRID. The use of UUID is strongly recommended. For CIMXML data files in RDF syntax conforming to IEC 61970-552, the mRID is mapped to rdf:ID or rdf:about attributes that identify CIM object elements. Default: "".
|
|
CIMPP::String | name |
| | The name is any free human readable and possibly non unique text naming the object. Default: "".
|
|
CIMPP::String | shortName |
| | The attribute is used for an exchange of a human readable short name with length of the string 12 characters maximum. Default: "".
|
|
|
static const char | debugName [] = "TransformerEnd" |
|
static const char | debugName [] = "IdentifiedObject" |
|
static const char | debugName [] = "BaseClass" |
A conducting connection point of a power transformer. It corresponds to a physical transformer winding terminal. In earlier CIM versions, the TransformerWinding class served a similar purpose, but this class is more flexible because it associates to terminal but is not a specialization of ConductingEquipment.
◆ addClassGetFnsToMap()
| void TransformerEnd::addClassGetFnsToMap |
( |
std::map< std::string, class_get_function > & | get_map | ) |
const |
|
overridevirtual |
◆ addEnumGetFnsToMap()
| void TransformerEnd::addEnumGetFnsToMap |
( |
std::map< std::string, get_function > & | get_map | ) |
const |
|
overridevirtual |
◆ addPrimitiveGetFnsToMap()
| void TransformerEnd::addPrimitiveGetFnsToMap |
( |
std::map< std::string, get_function > & | get_map | ) |
const |
|
overridevirtual |
◆ allAttrDetailsMap()
| std::map< std::string, AttrDetails > TransformerEnd::allAttrDetailsMap |
( |
| ) |
const |
|
overrideprotectedvirtual |
◆ debugString()
| const char * TransformerEnd::debugString |
( |
| ) |
const |
|
overridevirtual |
◆ getAttributeNames()
| const std::list< std::string > & TransformerEnd::getAttributeNames |
( |
| ) |
const |
|
overridevirtual |
◆ getAttributeNamespaceUrl()
| const std::string & TransformerEnd::getAttributeNamespaceUrl |
( |
const std::string & | attrName | ) |
const |
|
overridevirtual |
◆ getClassNamespaceUrl()
| const std::string & TransformerEnd::getClassNamespaceUrl |
( |
| ) |
const |
|
overridevirtual |
◆ getPossibleAttributeProfiles()
| const std::list< CGMESProfile > & TransformerEnd::getPossibleAttributeProfiles |
( |
const std::string & | attrName | ) |
const |
|
overridevirtual |
◆ getPossibleProfiles()
| const std::list< CGMESProfile > & TransformerEnd::getPossibleProfiles |
( |
| ) |
const |
|
overridevirtual |
◆ getPossibleProfilesIncludingAttributes()
| const std::list< CGMESProfile > & TransformerEnd::getPossibleProfilesIncludingAttributes |
( |
| ) |
const |
|
overridevirtual |
◆ getRecommendedProfile()
| const CGMESProfile & TransformerEnd::getRecommendedProfile |
( |
| ) |
const |
|
overridevirtual |
◆ isAssignableFrom()
| bool TransformerEnd::isAssignableFrom |
( |
BaseClass * | otherObject | ) |
const |
|
overridevirtual |
◆ grounded
Number for this transformer end, corresponding to the end`s order in the power transformer vector group or phase angle clock number. Highest voltage winding should be 1. Each end within a power transformer should have a unique subsequent end number. Note the transformer end number need not match the terminal sequence number. Default: 0 */ CIMPP::Integer endNumber;.
/** (for Yn and Zn connections) True if the neutral is solidly grounded. Default: false
The documentation for this class was generated from the following files: