10#include <unordered_map>
12#include "TurbineGovernorDynamics.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
17#include "ActivePower.hpp"
26 class GovSteamFV3 :
public TurbineGovernorDynamics
31 ~GovSteamFV3()
override;
126 static const char debugName[];
127 const char* debugString()
const override;
129 const std::list<std::string>& getAttributeNames()
const override;
131 const std::string& getClassNamespaceUrl()
const override;
132 const std::string& getAttributeNamespaceUrl(
const std::string& attrName)
const override;
134 const std::list<CGMESProfile>& getPossibleProfiles()
const override;
135 const CGMESProfile& getRecommendedProfile()
const override;
136 const std::list<CGMESProfile>& getPossibleAttributeProfiles(
const std::string& attrName)
const override;
137 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes()
const override;
139 static void addConstructToMap(std::unordered_map<std::string,
BaseClass* (*)()>& factory_map);
140 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
141 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
142 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
143 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map)
const override;
144 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
146 bool isAssignableFrom(
BaseClass* otherObject)
const override;
150 std::map<std::string, AttrDetails> allAttrDetailsMap()
const override;
Definition BaseClass.hpp:22
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Definition ActivePower.hpp:14
Definition BaseClassDefiner.hpp:12
A floating point number. The range is unspecified and not limited.
Definition Float.hpp:14
CIMPP::Seconds tb
Time until IV starts to reopen (Tb) (>= 0). Typical value = 0,98. Default: 0.0.
Definition GovSteamFV3.hpp:115
CIMPP::Float uc
Maximum valve closing velocity (Uc). Unit = PU / s. Typical value = -1. Default: 0....
Definition GovSteamFV3.hpp:121
CIMPP::Seconds t4
Inlet piping/steam bowl time constant (T4) (>= 0). Typical value = 0,2. Default: 0....
Definition GovSteamFV3.hpp:103
CIMPP::Seconds t2
Governor lag time constant (T2) (>= 0). Typical value = 0. Default: 0.0.
Definition GovSteamFV3.hpp:97
CIMPP::PU k2
Fraction of turbine power developed after second boiler pass (K2). Typical value = 0,...
Definition GovSteamFV3.hpp:58
CIMPP::PU gv6
Nonlinear gain valve position point 6 (GV6). Typical value = 0. Default: 0.0.
Definition GovSteamFV3.hpp:49
CIMPP::PU prmax
Max. pressure in reheater (Prmax). Typical value = 1. Default: 0.0.
Definition GovSteamFV3.hpp:91
CIMPP::PU pgv4
Nonlinear gain power value point 4 (Pgv4). Typical value = 0,98. Default: 0.0.
Definition GovSteamFV3.hpp:76
CIMPP::Seconds t3
Valve positioner time constant (T3) (> 0). Typical value = 0. Default: 0.0.
Definition GovSteamFV3.hpp:100
CIMPP::PU pgv2
Nonlinear gain power value point 2 (Pgv2). Typical value = 0,75. Default: 0.0.
Definition GovSteamFV3.hpp:70
CIMPP::PU pgv5
Nonlinear gain power value point 5 (Pgv5). Typical value = 1. Default: 0.0.
Definition GovSteamFV3.hpp:79
CIMPP::PU gv1
Nonlinear gain valve position point 1 (GV1). Typical value = 0. Default: 0.0.
Definition GovSteamFV3.hpp:34
CIMPP::Seconds t1
Governor lead time constant (T1) (>= 0). Typical value = 0. Default: 0.0.
Definition GovSteamFV3.hpp:94
CIMPP::PU gv3
Nonlinear gain valve position point 3 (GV3). Typical value = 0,5. Default: 0.0.
Definition GovSteamFV3.hpp:40
CIMPP::Seconds tc
Time until IV is fully open (Tc) (>= 0). Typical value = 0,99. Default: 0.0.
Definition GovSteamFV3.hpp:118
CIMPP::PU pgv3
Nonlinear gain power value point 3 (Pgv3). Typical value = 0,91. Default: 0.0.
Definition GovSteamFV3.hpp:73
CIMPP::PU gv5
Nonlinear gain valve position point 5 (GV5). Typical value = 1. Default: 0.0.
Definition GovSteamFV3.hpp:46
CIMPP::Seconds t6
Time constant of crossover or third boiler pass (T6) (>= 0). Typical value = 10. Default: 0....
Definition GovSteamFV3.hpp:109
CIMPP::PU gv4
Nonlinear gain valve position point 4 (GV4). Typical value = 0,6. Default: 0.0.
Definition GovSteamFV3.hpp:43
CIMPP::PU k1
Fraction of turbine power developed after first boiler pass (K1). Typical value = 0,...
Definition GovSteamFV3.hpp:55
CIMPP::Float uo
Maximum valve opening velocity (Uo). Unit = PU / s. Typical value = 0,1. Default: 0....
Definition GovSteamFV3.hpp:124
CIMPP::Seconds t5
Time constant of second boiler pass (i.e. reheater) (T5) (> 0 if fast valving is used,...
Definition GovSteamFV3.hpp:106
CIMPP::PU pmin
Minimum valve opening, PU of MWbase (Pmin) (< GovSteamFV3.pmax). Typical value = 0....
Definition GovSteamFV3.hpp:88
CIMPP::ActivePower mwbase
Base for power values (MWbase) (> 0). Unit = MW. Default: 0.0.
Definition GovSteamFV3.hpp:64
CIMPP::Seconds ta
Time to close intercept valve (IV) (Ta) (>= 0). Typical value = 0,97. Default: 0.0.
Definition GovSteamFV3.hpp:112
CIMPP::PU k
Governor gain, (reciprocal of droop) (K). Typical value = 20. Default: 0.0.
Definition GovSteamFV3.hpp:52
CIMPP::PU gv2
Nonlinear gain valve position point 2 (GV2). Typical value = 0,4. Default: 0.0.
Definition GovSteamFV3.hpp:37
CIMPP::PU k3
Fraction of hp turbine power developed after crossover or third boiler pass (K3). Typical value = 0,...
Definition GovSteamFV3.hpp:61
CIMPP::PU pgv6
Nonlinear gain power value point 6 (Pgv6). Typical value = 0. Default: 0.0.
Definition GovSteamFV3.hpp:82
CIMPP::PU pmax
Maximum valve opening, PU of MWbase (Pmax) (> GovSteamFV3.pmin). Typical value = 1....
Definition GovSteamFV3.hpp:85
CIMPP::PU pgv1
Nonlinear gain power value point 1 (Pgv1). Typical value = 0. Default: 0.0.
Definition GovSteamFV3.hpp:67
Per Unit - a positive or negative value referred to a defined base. Values typically range from -10 t...
Definition PU.hpp:14
Time, in seconds.
Definition Seconds.hpp:14