10#include <unordered_map>
12#include "TurbineGovernorDynamics.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
17#include "ActivePower.hpp"
25 class GovHydroWPID :
public TurbineGovernorDynamics
30 ~GovHydroWPID()
override;
98 static const char debugName[];
99 const char* debugString()
const override;
101 const std::list<std::string>& getAttributeNames()
const override;
103 const std::string& getClassNamespaceUrl()
const override;
104 const std::string& getAttributeNamespaceUrl(
const std::string& attrName)
const override;
106 const std::list<CGMESProfile>& getPossibleProfiles()
const override;
107 const CGMESProfile& getRecommendedProfile()
const override;
108 const std::list<CGMESProfile>& getPossibleAttributeProfiles(
const std::string& attrName)
const override;
109 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes()
const override;
111 static void addConstructToMap(std::unordered_map<std::string,
BaseClass* (*)()>& factory_map);
112 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
113 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
114 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
115 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map)
const override;
116 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
118 bool isAssignableFrom(
BaseClass* otherObject)
const override;
122 std::map<std::string, AttrDetails> allAttrDetailsMap()
const override;
Definition BaseClass.hpp:22
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Definition ActivePower.hpp:14
Definition BaseClassDefiner.hpp:12
CIMPP::Seconds ta
Controller time constant (Ta) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroWPID.hpp:81
CIMPP::PU gv1
Gate position 1 (Gv1). Default: 0.0.
Definition GovHydroWPID.hpp:42
CIMPP::PU pgv1
Output at Gv1 PU of MWbase (Pgv1). Default: 0.0.
Definition GovHydroWPID.hpp:63
CIMPP::ActivePower mwbase
Base for power values (MWbase) (> 0). Unit = MW. Default: 0.0.
Definition GovHydroWPID.hpp:60
CIMPP::Seconds tb
Gate servo time constant (Tb) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroWPID.hpp:84
CIMPP::PU velmax
Maximum gate opening velocity (Velmax) (> GovHydroWPID.velmin). Unit = PU / s. Typical value = 0....
Definition GovHydroWPID.hpp:93
CIMPP::PU kd
Derivative gain (Kd). Typical value = 1,11. Default: 0.0.
Definition GovHydroWPID.hpp:51
CIMPP::PU gatmin
Gate opening limit minimum (Gatmin) (< GovHydroWPID.gatmax). Default: 0.0.
Definition GovHydroWPID.hpp:39
CIMPP::PU ki
Reset gain (Ki). Typical value = 0,36. Default: 0.0.
Definition GovHydroWPID.hpp:54
CIMPP::PU pmin
Minimum power output (Pmin) (< GovHydroWPID.pmax). Default: 0.0.
Definition GovHydroWPID.hpp:75
CIMPP::Seconds tw
Water inertia time constant (Tw) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroWPID.hpp:90
CIMPP::PU pgv2
Output at Gv2 PU of MWbase (Pgv2). Default: 0.0.
Definition GovHydroWPID.hpp:66
CIMPP::PU d
Turbine damping factor (D). Unit = delta P / delta speed. Default: 0.0.
Definition GovHydroWPID.hpp:33
CIMPP::PU kp
Proportional gain (Kp). Typical value = 0,1. Default: 0.0.
Definition GovHydroWPID.hpp:57
CIMPP::PU pmax
Maximum power output (Pmax) (> GovHydroWPID.pmin). Default: 0.0.
Definition GovHydroWPID.hpp:72
CIMPP::PU gv3
Gate position 3 (Gv3) (= 1,0). Default: 0.0.
Definition GovHydroWPID.hpp:48
CIMPP::Seconds treg
Speed detector time constant (Treg) (>= 0). Default: 0.0.
Definition GovHydroWPID.hpp:87
CIMPP::PU pgv3
Output at Gv3 PU of MWbase (Pgv3). Default: 0.0.
Definition GovHydroWPID.hpp:69
CIMPP::PU gatmax
Gate opening limit maximum (Gatmax) (> GovHydroWPID.gatmin). Default: 0.0.
Definition GovHydroWPID.hpp:36
CIMPP::PU gv2
Gate position 2 (Gv2). Default: 0.0.
Definition GovHydroWPID.hpp:45
CIMPP::PU reg
Permanent drop (Reg). Default: 0.0.
Definition GovHydroWPID.hpp:78
CIMPP::PU velmin
Maximum gate closing velocity (Velmin) (< GovHydroWPID.velmax). Unit = PU / s. Typical value = 0....
Definition GovHydroWPID.hpp:96
Per Unit - a positive or negative value referred to a defined base. Values typically range from -10 t...
Definition PU.hpp:14
Time, in seconds.
Definition Seconds.hpp:14