10#include <unordered_map>
12#include "TurbineGovernorDynamics.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
17#include "ActivePower.hpp"
20#include "Frequency.hpp"
28 class GovHydroR :
public TurbineGovernorDynamics
33 ~GovHydroR()
override;
161 static const char debugName[];
162 const char* debugString()
const override;
164 const std::list<std::string>& getAttributeNames()
const override;
166 const std::string& getClassNamespaceUrl()
const override;
167 const std::string& getAttributeNamespaceUrl(
const std::string& attrName)
const override;
169 const std::list<CGMESProfile>& getPossibleProfiles()
const override;
170 const CGMESProfile& getRecommendedProfile()
const override;
171 const std::list<CGMESProfile>& getPossibleAttributeProfiles(
const std::string& attrName)
const override;
172 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes()
const override;
174 static void addConstructToMap(std::unordered_map<std::string,
BaseClass* (*)()>& factory_map);
175 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
176 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
177 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
178 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map)
const override;
179 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
181 bool isAssignableFrom(
BaseClass* otherObject)
const override;
185 std::map<std::string, AttrDetails> allAttrDetailsMap()
const override;
Definition BaseClass.hpp:22
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Definition ActivePower.hpp:14
Definition BaseClassDefiner.hpp:12
Definition Boolean.hpp:13
A floating point number. The range is unspecified and not limited.
Definition Float.hpp:14
Cycles per second.
Definition Frequency.hpp:14
CIMPP::PU qnl
No-load turbine flow at nominal head (Qnl). Typical value = 0,08. Default: 0.0.
Definition GovHydroR.hpp:114
CIMPP::Frequency db1
Intentional dead-band width (db1). Unit = Hz. Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:39
CIMPP::Float velop
Maximum gate opening velocity (Velop). Unit = PU / s. Typical value = 0,2. Default: 0....
Definition GovHydroR.hpp:159
CIMPP::Seconds t6
Lag time constant 3 (T6) (>= 0). Typical value = 0,05. Default: 0.0.
Definition GovHydroR.hpp:135
CIMPP::PU ki
Integral gain (Ki). Typical value = 0,5. Default: 0.0.
Definition GovHydroR.hpp:84
CIMPP::PU gv1
Nonlinear gain point 1, PU gv (Gv1). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:57
CIMPP::Seconds tp
Gate servo time constant (Tp) (>= 0). Typical value = 0,05. Default: 0.0.
Definition GovHydroR.hpp:147
CIMPP::PU pmax
Maximum gate opening, PU of MWbase (Pmax) (> GovHydroR.pmin). Typical value = 1. Default: 0....
Definition GovHydroR.hpp:108
CIMPP::PU pgv3
Nonlinear gain point 3, PU power (Pgv3). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:96
CIMPP::Seconds tw
Water inertia time constant (Tw) (> 0). Typical value = 1. Default: 0.0.
Definition GovHydroR.hpp:153
CIMPP::PU pgv6
Nonlinear gain point 6, PU power (Pgv6). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:105
CIMPP::PU gmin
Minimum governor output (Gmin) (< GovHydroR.gmax). Typical value = -0,05. Default: 0....
Definition GovHydroR.hpp:54
CIMPP::ActivePower mwbase
Base for power values (MWbase) (> 0). Unit = MW. Default: 0.0.
Definition GovHydroR.hpp:87
CIMPP::PU at
Turbine gain (At). Typical value = 1,2. Default: 0.0.
Definition GovHydroR.hpp:36
CIMPP::Seconds t2
Lag time constant 1 (T2) (>= 0). Typical value = 0,1. Default: 0.0.
Definition GovHydroR.hpp:123
CIMPP::Seconds t4
Lag time constant 2 (T4) (>= 0). Typical value = 0,1. Default: 0.0.
Definition GovHydroR.hpp:129
CIMPP::PU pmin
Minimum gate opening, PU of MWbase (Pmin) (< GovHydroR.pmax). Typical value = 0. Default: 0....
Definition GovHydroR.hpp:111
CIMPP::Boolean inputSignal
Input signal switch (Flag). true = Pe input is used false = feedback is received from CV....
Definition GovHydroR.hpp:78
CIMPP::PU pgv4
Nonlinear gain point 4, PU power (Pgv4). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:99
CIMPP::Seconds t1
Lead time constant 1 (T1) (>= 0). Typical value = 1,5. Default: 0.0.
Definition GovHydroR.hpp:120
CIMPP::PU pgv5
Nonlinear gain point 5, PU power (Pgv5). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:102
CIMPP::Seconds t7
Lead time constant 4 (T7) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:138
CIMPP::ActivePower db2
Unintentional dead-band (db2). Unit = MW. Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:42
CIMPP::Seconds t8
Lag time constant 4 (T8) (>= 0). Typical value = 0,05. Default: 0.0.
Definition GovHydroR.hpp:141
CIMPP::Frequency eps
Intentional db hysteresis (eps). Unit = Hz. Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:48
CIMPP::Seconds t5
Lead time constant 3 (T5) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:132
CIMPP::PU kg
Gate servo gain (Kg). Typical value = 2. Default: 0.0.
Definition GovHydroR.hpp:81
CIMPP::PU pgv2
Nonlinear gain point 2, PU power (Pgv2). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:93
CIMPP::PU r
Steady-state droop (R). Typical value = 0,05. Default: 0.0.
Definition GovHydroR.hpp:117
CIMPP::PU gv6
Nonlinear gain point 6, PU gv (Gv6). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:72
CIMPP::Seconds t3
Lead time constant 2 (T3) (>= 0). Typical value = 1,5. Default: 0.0.
Definition GovHydroR.hpp:126
CIMPP::Seconds tt
Power feedback time constant (Tt) (>= 0). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:150
CIMPP::PU gv5
Nonlinear gain point 5, PU gv (Gv5). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:69
CIMPP::PU dturb
Turbine damping factor (Dturb). Typical value = 0,2. Default: 0.0.
Definition GovHydroR.hpp:45
CIMPP::Float velcl
Maximum gate closing velocity (Velcl). Unit = PU / s. Typical value = -0,2. Default: 0....
Definition GovHydroR.hpp:156
CIMPP::PU gv2
Nonlinear gain point 2, PU gv (Gv2). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:60
CIMPP::PU gv4
Nonlinear gain point 4, PU gv (Gv4). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:66
CIMPP::Seconds td
Input filter time constant (Td) (>= 0). Typical value = 0,05. Default: 0.0.
Definition GovHydroR.hpp:144
CIMPP::PU gv3
Nonlinear gain point 3, PU gv (Gv3). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:63
CIMPP::PU gmax
Maximum governor output (Gmax) (> GovHydroR.gmin). Typical value = 1,05. Default: 0....
Definition GovHydroR.hpp:51
CIMPP::PU h0
Turbine nominal head (H0). Typical value = 1. Default: 0.0.
Definition GovHydroR.hpp:75
CIMPP::PU pgv1
Nonlinear gain point 1, PU power (Pgv1). Typical value = 0. Default: 0.0.
Definition GovHydroR.hpp:90
Per Unit - a positive or negative value referred to a defined base. Values typically range from -10 t...
Definition PU.hpp:14
Time, in seconds.
Definition Seconds.hpp:14