1#ifndef ExternalNetworkInjection_H
2#define ExternalNetworkInjection_H
10#include <unordered_map>
12#include "RegulatingCondEq.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
17#include "ActivePower.hpp"
18#include "ActivePowerPerFrequency.hpp"
20#include "CurrentFlow.hpp"
24#include "ReactivePower.hpp"
30 class ExternalNetworkInjection :
public RegulatingCondEq
34 ExternalNetworkInjection();
35 ~ExternalNetworkInjection()
override;
91 static const char debugName[];
92 const char* debugString()
const override;
94 const std::list<std::string>& getAttributeNames()
const override;
96 const std::string& getClassNamespaceUrl()
const override;
97 const std::string& getAttributeNamespaceUrl(
const std::string& attrName)
const override;
99 const std::list<CGMESProfile>& getPossibleProfiles()
const override;
100 const CGMESProfile& getRecommendedProfile()
const override;
101 const std::list<CGMESProfile>& getPossibleAttributeProfiles(
const std::string& attrName)
const override;
102 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes()
const override;
104 static void addConstructToMap(std::unordered_map<std::string,
BaseClass* (*)()>& factory_map);
105 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
106 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
107 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
108 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map)
const override;
109 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
111 bool isAssignableFrom(
BaseClass* otherObject)
const override;
115 std::map<std::string, AttrDetails> allAttrDetailsMap()
const override;
118 BaseClass* ExternalNetworkInjection_factory();
Definition BaseClass.hpp:22
Active power variation with frequency.
Definition ActivePowerPerFrequency.hpp:14
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Definition ActivePower.hpp:14
Definition BaseClassDefiner.hpp:12
Definition Boolean.hpp:13
Electrical current with sign convention: positive flow is out of the conducting equipment into the co...
Definition CurrentFlow.hpp:14
CIMPP::Float minZ0ToZ1Ratio
Minimum ratio of zero sequence impedance to its positive sequence impedance (Z(0)/Z(1) min)....
Definition ExternalNetworkInjection.hpp:77
CIMPP::ActivePower p
Active power injection. Load sign convention is used, i.e. positive sign means flow out from a node....
Definition ExternalNetworkInjection.hpp:80
CIMPP::ActivePower maxP
Indicates whether initial symmetrical short-circuit current and power have been calculated according ...
Definition ExternalNetworkInjection.hpp:47
CIMPP::Float maxZ0ToZ1Ratio
Maximum ratio of zero sequence impedance to its positive sequence impedance (Z(0)/Z(1) max)....
Definition ExternalNetworkInjection.hpp:59
CIMPP::Float maxR1ToX1Ratio
Maximum ratio of positive sequence resistance of Network Feeder to its positive sequence reactance (R...
Definition ExternalNetworkInjection.hpp:56
CIMPP::ReactivePower minQ
Minimum reactive power limit. It is used for modelling of infeed for load flow exchange and not for s...
Definition ExternalNetworkInjection.hpp:68
CIMPP::Float minR1ToX1Ratio
Indicates whether initial symmetrical short-circuit current and power have been calculated according ...
Definition ExternalNetworkInjection.hpp:74
CIMPP::Float maxR0ToX0Ratio
Maximum ratio of zero sequence resistance of Network Feeder to its zero sequence reactance (R(0)/X(0)...
Definition ExternalNetworkInjection.hpp:53
CIMPP::ActivePower minP
Minimum initial symmetrical short-circuit currents (Ik min) in A (Ik = Sk`/(SQRT(3) Un))....
Definition ExternalNetworkInjection.hpp:65
CIMPP::ActivePowerPerFrequency governorSCD
Power Frequency Bias. This is the change in power injection divided by the change in frequency and ne...
Definition ExternalNetworkInjection.hpp:38
CIMPP::ReactivePower q
Reactive power injection. Load sign convention is used, i.e. positive sign means flow out from a node...
Definition ExternalNetworkInjection.hpp:83
CIMPP::ReactivePower maxQ
Maximum reactive power limit. It is used for modelling of infeed for load flow exchange and not for s...
Definition ExternalNetworkInjection.hpp:50
CIMPP::Integer referencePriority
Priority of unit for use as powerflow voltage phase angle reference bus selection....
Definition ExternalNetworkInjection.hpp:86
CIMPP::PU voltageFactor
Voltage factor in pu, which was used to calculate short-circuit current Ik and power Sk....
Definition ExternalNetworkInjection.hpp:89
A floating point number. The range is unspecified and not limited.
Definition Float.hpp:14
Definition Integer.hpp:13
Per Unit - a positive or negative value referred to a defined base. Values typically range from -10 t...
Definition PU.hpp:14
Product of RMS value of the voltage and the RMS value of the quadrature component of the current.
Definition ReactivePower.hpp:14