10#include <unordered_map>
12#include "ExcitationSystemDynamics.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
18#include "ExcST6BOELselectorKind.hpp"
26 class ExcST6B :
public ExcitationSystemDynamics
102 static const char debugName[];
103 const char* debugString()
const override;
105 const std::list<std::string>& getAttributeNames()
const override;
107 const std::string& getClassNamespaceUrl()
const override;
108 const std::string& getAttributeNamespaceUrl(
const std::string& attrName)
const override;
110 const std::list<CGMESProfile>& getPossibleProfiles()
const override;
111 const CGMESProfile& getRecommendedProfile()
const override;
112 const std::list<CGMESProfile>& getPossibleAttributeProfiles(
const std::string& attrName)
const override;
113 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes()
const override;
115 static void addConstructToMap(std::unordered_map<std::string,
BaseClass* (*)()>& factory_map);
116 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
117 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
118 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
119 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map)
const override;
120 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
122 bool isAssignableFrom(
BaseClass* otherObject)
const override;
126 std::map<std::string, AttrDetails> allAttrDetailsMap()
const override;
Definition BaseClass.hpp:22
Definition BaseClassDefiner.hpp:12
Definition Boolean.hpp:13
Types of connections for the OEL input used for static excitation systems type 6B.
Definition ExcST6BOELselectorKind.hpp:14
CIMPP::Boolean vilim
Selector (Vilim). true = Vimin-Vimax limiter is active false = Vimin-Vimax limiter is not active....
Definition ExcST6B.hpp:82
CIMPP::Seconds ts
Rectifier firing time constant (Ts) (>= 0). Typical value = 0. Default: 0.0.
Definition ExcST6B.hpp:70
CIMPP::PU vrmax
Maximum voltage regulator output (Vrmax) (> 0). Typical value = 4,81. Default: 0.0.
Definition ExcST6B.hpp:94
CIMPP::PU kcl
Exciter output current limit adjustment (Kcl) (> 0). Typical value = 1,0577. Default: 0....
Definition ExcST6B.hpp:40
CIMPP::PU vamin
Minimum voltage regulator output (Vamin) (< 0). Typical value = -3,85. Default: 0....
Definition ExcST6B.hpp:79
CIMPP::Boolean vmult
Selector (vmult). true = multiply regulator output by terminal voltage false = do not multiply regula...
Definition ExcST6B.hpp:91
CIMPP::ExcST6BOELselectorKind oelin
OEL input selector (OELin). Typical value = noOELinput (corresponds to OELin = 0 on diagram)....
Definition ExcST6B.hpp:64
CIMPP::PU vrmin
Minimum voltage regulator output (Vrmin) (< 0). Typical value = -3,85. Default: 0....
Definition ExcST6B.hpp:97
CIMPP::PU kvd
Voltage regulator derivative gain (Kvd). Typical value = 0. Default: 0.0.
Definition ExcST6B.hpp:61
CIMPP::PU km
Forward gain constant of the inner loop field regulator (Km). Typical value = 1. Default: 0....
Definition ExcST6B.hpp:55
CIMPP::PU kff
Pre-control gain constant of the inner loop field regulator (Kff). Typical value = 1....
Definition ExcST6B.hpp:43
CIMPP::PU klr
Exciter output current limit adjustment (Kcl) (> 0). Typical value = 17,33. Default: 0....
Definition ExcST6B.hpp:52
CIMPP::PU xc
Excitation source reactance (Xc). Typical value = 0,05. Default: 0.0.
Definition ExcST6B.hpp:100
CIMPP::PU vimin
Minimum voltage regulator input limit (Vimin) (< ExcST6B.vimax). Typical value = -10....
Definition ExcST6B.hpp:88
CIMPP::Boolean k1
Selector (K1). true = feedback is from Ifd false = feedback is not from Ifd. Typical value = true....
Definition ExcST6B.hpp:37
CIMPP::PU kia
Voltage regulator integral gain (Kia) (> 0). Typical value = 45,094. Default: 0.0.
Definition ExcST6B.hpp:49
CIMPP::PU vamax
Maximum voltage regulator output (Vamax) (> 0). Typical value = 4,81. Default: 0.0.
Definition ExcST6B.hpp:76
CIMPP::PU vimax
Maximum voltage regulator input limit (Vimax) (> ExcST6B.vimin). Typical value = 10....
Definition ExcST6B.hpp:85
CIMPP::PU kpa
Voltage regulator proportional gain (Kpa) (> 0). Typical value = 18,038. Default: 0....
Definition ExcST6B.hpp:58
CIMPP::PU kg
Feedback gain constant of the inner loop field regulator (Kg) (>= 0). Typical value = 1....
Definition ExcST6B.hpp:46
CIMPP::Seconds tvd
Voltage regulator derivative gain (Tvd) (>= 0). Typical value = 0. Default: 0.0.
Definition ExcST6B.hpp:73
CIMPP::PU ilr
Exciter output current limit reference (Ilr) (> 0). Typical value = 4,164. Default: 0....
Definition ExcST6B.hpp:34
CIMPP::Seconds tg
Feedback time constant of inner loop field voltage regulator (Tg) (>= 0). Typical value = 0,...
Definition ExcST6B.hpp:67
Per Unit - a positive or negative value referred to a defined base. Values typically range from -10 t...
Definition PU.hpp:14
Time, in seconds.
Definition Seconds.hpp:14