1#ifndef EquivalentInjection_H
2#define EquivalentInjection_H
10#include <unordered_map>
12#include "EquivalentEquipment.hpp"
13#include "BaseClassDefiner.hpp"
14#include "CGMESProfile.hpp"
15#include "CimClassDetails.hpp"
17#include "ActivePower.hpp"
19#include "Reactance.hpp"
20#include "ReactivePower.hpp"
21#include "Resistance.hpp"
29 class EquivalentInjection :
public EquivalentEquipment
33 EquivalentInjection();
34 ~EquivalentInjection()
override;
84 static const char debugName[];
85 const char* debugString()
const override;
87 const std::list<std::string>& getAttributeNames()
const override;
89 const std::string& getClassNamespaceUrl()
const override;
90 const std::string& getAttributeNamespaceUrl(
const std::string& attrName)
const override;
92 const std::list<CGMESProfile>& getPossibleProfiles()
const override;
93 const CGMESProfile& getRecommendedProfile()
const override;
94 const std::list<CGMESProfile>& getPossibleAttributeProfiles(
const std::string& attrName)
const override;
95 const std::list<CGMESProfile>& getPossibleProfilesIncludingAttributes()
const override;
97 static void addConstructToMap(std::unordered_map<std::string,
BaseClass* (*)()>& factory_map);
98 static void addPrimitiveAssignFnsToMap(std::unordered_map<std::string, assign_function>& assign_map);
99 static void addClassAssignFnsToMap(std::unordered_map<std::string, class_assign_function>& assign_map);
100 void addPrimitiveGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
101 void addClassGetFnsToMap(std::map<std::string, class_get_function>& get_map)
const override;
102 void addEnumGetFnsToMap(std::map<std::string, get_function>& get_map)
const override;
104 bool isAssignableFrom(
BaseClass* otherObject)
const override;
108 std::map<std::string, AttrDetails> allAttrDetailsMap()
const override;
111 BaseClass* EquivalentInjection_factory();
Definition BaseClass.hpp:22
Product of RMS value of the voltage and the RMS value of the in-phase component of the current.
Definition ActivePower.hpp:14
Definition BaseClassDefiner.hpp:12
Definition Boolean.hpp:13
CIMPP::Boolean regulationStatus
Specifies the regulation status of the EquivalentInjection. True is regulating. False is not regulati...
Definition EquivalentInjection.hpp:70
CIMPP::Resistance r2
Negative sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a...
Definition EquivalentInjection.hpp:64
CIMPP::Boolean regulationCapability
Specifies whether or not the EquivalentInjection has the capability to regulate the local voltage....
Definition EquivalentInjection.hpp:67
CIMPP::ActivePower minP
Minimum active power of the injection. Default: 0.0.
Definition EquivalentInjection.hpp:46
CIMPP::Reactance x0
Zero sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a resu...
Definition EquivalentInjection.hpp:79
CIMPP::Voltage regulationTarget
The target voltage for voltage regulation. The attribute shall be a positive value....
Definition EquivalentInjection.hpp:73
CIMPP::ActivePower p
Equivalent active power injection. Load sign convention is used, i.e. positive sign means flow out fr...
Definition EquivalentInjection.hpp:52
CIMPP::Resistance r0
Zero sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a res...
Definition EquivalentInjection.hpp:61
CIMPP::Reactance x
Positive sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a ...
Definition EquivalentInjection.hpp:76
CIMPP::Reactance x2
Negative sequence reactance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a ...
Definition EquivalentInjection.hpp:82
CIMPP::Resistance r
Positive sequence resistance. Used to represent Extended-Ward (IEC 60909). Usage : Extended-Ward is a...
Definition EquivalentInjection.hpp:58
CIMPP::ReactivePower q
Equivalent reactive power injection. Load sign convention is used, i.e. positive sign means flow out ...
Definition EquivalentInjection.hpp:55
CIMPP::ReactivePower maxQ
Maximum reactive power of the injection. Used for modelling of infeed for load flow exchange....
Definition EquivalentInjection.hpp:43
CIMPP::ReactiveCapabilityCurve * ReactiveCapabilityCurve
The reactive capability curve used by this equivalent injection. Default: nullptr.
Definition EquivalentInjection.hpp:37
CIMPP::ReactivePower minQ
Minimum reactive power of the injection. Used for modelling of infeed for load flow exchange....
Definition EquivalentInjection.hpp:49
CIMPP::ActivePower maxP
Maximum active power of the injection. Default: 0.0.
Definition EquivalentInjection.hpp:40
Reactance (imaginary part of impedance), at rated frequency.
Definition Reactance.hpp:14
Reactive power rating envelope versus the synchronous machine's active power, in both the generating ...
Definition ReactiveCapabilityCurve.hpp:25
Product of RMS value of the voltage and the RMS value of the quadrature component of the current.
Definition ReactivePower.hpp:14
Resistance (real part of impedance).
Definition Resistance.hpp:14
Electrical voltage, can be both AC and DC.
Definition Voltage.hpp:14